Specifications
Table Of Contents
- IBM PC Server and Novell NetWare Integration Guide
- Abstract
- Contents
- Figures
- Tables
- Special Notices
- Preface
- Chapter 1. IBM PC Server Technologies
- Processors
- Clock Rate
- External Interfaces
- Processor Types
- Multiprocessing
- Memory
- Caches
- Memory Interleaving
- Dual Path Buses
- SynchroStream Technology
- Memory Error Detection and Correction
- Standard (Parity) Memory
- Error Correcting Code (ECC)
- Error Correcting Code- Parity Memory (ECC- P)
- ECC on SIMMs (EOS) Memory
- Performance Impact
- Memory Options and Speed
- Bus Architectures
- ISA Bus
- EISA Bus
- Micro Channel Bus
- PCI Bus
- Disk Subsystem
- Hard Disk Interfaces
- SCSI Technology
- SCSI Adapters
- Hard Disk Drives
- RAID Technology
- RAID Classifications
- Recommendations
- LAN Subsystem
- Shared RAM Adapters
- Bus Master Adapters
- PeerMaster Technology
- Security Features
- Tamper- Evident Cover
- Secure I/ O Cables
- Passwords
- Secure Removable Media
- Selectable Drive Startup
- Unattended Start Mode
- Systems Management
- DMI
- SNMP
- NetFinity
- SystemView
- Fault Tolerance
- NetWare SFT III
- Uninterruptible Power Supply (UPS)
- APC PowerChute
- Chapter 2. IBM PC Server Family Overview
- Chapter 3. Hardware Configuration
- The Setup Program
- Main Menu
- Advanced Menu
- Security
- EISA Configuration Utility
- SCSI Select Utility Program
- System Programs
- Starting From the System Partition
- Starting From the Reference Diskette
- Main Menu Options
- Backup/ Restore System Programs Menu
- Set Configuration Menu
- Set Features Menu
- Test the Computer
- More Utilities Menu
- Advanced Diagnostic Program
- RAID Controller Utility
- Drive Information
- Formatting the Disks
- Defining a Hot- Spare Disk
- Creating a Disk Array
- Defining Logical Drives
- Setting the Write Policy
- Initializing the Array
- Backup/ Restoring the Configuration
- Chapter 4. Novell NetWare Installation
- ServerGuide Overview
- Starting ServerGuide
- Installing NetWare 4.1 with ServerGuide
- Installing NetWare 3.12 with Diskettes
- Hardware Requirements
- Software Requirements
- Information Requested at Time of Installation
- Installation Files
- Installation Procedure
- Installing NetWare 4.1 with the Original CD- ROM
- Hardware Requirements
- Software Requirements
- Installation Procedure
- NetFinity Services for NetWare
- System Requirements
- Installing NetFinity Services for NetWare
- The RAID Administration for NetWare Utility
- Installing the Utility
- Hard Disk Failure Simulation
- Simulating with a Hot Spare Drive
- Simulating without a Hot Spare Drive
- Chapter 5. Performance Tuning
- Appendix A. EISA Configuration File
- Appendix B. Hardware Compatibility, Device Driver, and Software Patch Information
- Appendix C. Configuring DOS CD-ROM Support
- List of Abbreviations
- Index
- Special Characters C
- Numerics
- A
- B
- D
- E
- F
- H
- M
- I
- N
- K
- L
- O
- P
- S
- Q
- R
- T
- U
- V
- W
- Z
- ITSO Technical Bulletin Evaluation RED000
1.10.1 NetWare SFT III
NetWare SFT III is a special version of the NetWare 3.x or 4.x NOS which adds a
high degree of fault tolerance. It is composed of two servers, a primary and a
secondary, which are mirrored together.
To clients on the network, only the primary server appears to be active. The
secondary server remains in the background; however, it maintains the same
essential memory image and the same disk contents as the primary server. If
the primary server fails or halts, the secondary server automatically becomes
the new primary server. This process is instantaneous and transparent to any
client using the server.
NetWare SFT III has the following hardware requirements:
1. Two Servers (identical in make and model with at least an i386 processor
2. 12 MB of RAM minimum in each server
3. Identical disk subsystems on each server
4. Identical video subsystems on each server
5. Two Mirrored Server Link Adapters (can be either fiber, coaxial or shielded
twisted pair (STP) attached)
NetWare SFT III has the following software requirements:
1. NetWare SFT III (5, 10, 20, 50, 100, 250 user versions)
2. Identical DOS on each server (V3.1 or higher)
The two servers are not required to be on the same LAN segments or even
required to have the same types of LAN adapters. The only requirement is that
the servers be on the same internetwork and that all clients can get LAN packets
to/from both of them.
1.10.1.1 SFT III Server Roles
A single SFT III server can be primary unmirrored, primary mirrored, or
secondary mirrored at any given moment. When two servers are mirrored, they
keep each other informed and aware of each other′s role. When the secondary
server finds that the primary server is no longer responding to its inquiries, it
must determine whether the primary server is inoperable. If the primary server
is inoperable, the secondary server takes over as the primary server, running
without a mirrored partner.
The designation of primary or secondary server can change at any time. When
the two servers are powered up and synchronized, the server that is activated
first becomes the primary server. Once the roles of the servers have been
defined, if the primary server fails, the secondary takes over as the primary and
begins to service network clients.
1.10.1.2 Communication links
Each server is attached to two types of communication links:
•
IPX internet link
•
Mirrored Server Link (MSL)
IPX internet link:
The IPX internet link is used for communicating with clients
and for sending
server state
packets between the primary and secondary
servers. The server state packets are also used to monitor the status of the
internetwork.
48 NetWare Integration Guide