Specifications
Table Of Contents
- IBM PC Server and Novell NetWare Integration Guide
- Abstract
- Contents
- Figures
- Tables
- Special Notices
- Preface
- Chapter 1. IBM PC Server Technologies
- Processors
- Clock Rate
- External Interfaces
- Processor Types
- Multiprocessing
- Memory
- Caches
- Memory Interleaving
- Dual Path Buses
- SynchroStream Technology
- Memory Error Detection and Correction
- Standard (Parity) Memory
- Error Correcting Code (ECC)
- Error Correcting Code- Parity Memory (ECC- P)
- ECC on SIMMs (EOS) Memory
- Performance Impact
- Memory Options and Speed
- Bus Architectures
- ISA Bus
- EISA Bus
- Micro Channel Bus
- PCI Bus
- Disk Subsystem
- Hard Disk Interfaces
- SCSI Technology
- SCSI Adapters
- Hard Disk Drives
- RAID Technology
- RAID Classifications
- Recommendations
- LAN Subsystem
- Shared RAM Adapters
- Bus Master Adapters
- PeerMaster Technology
- Security Features
- Tamper- Evident Cover
- Secure I/ O Cables
- Passwords
- Secure Removable Media
- Selectable Drive Startup
- Unattended Start Mode
- Systems Management
- DMI
- SNMP
- NetFinity
- SystemView
- Fault Tolerance
- NetWare SFT III
- Uninterruptible Power Supply (UPS)
- APC PowerChute
- Chapter 2. IBM PC Server Family Overview
- Chapter 3. Hardware Configuration
- The Setup Program
- Main Menu
- Advanced Menu
- Security
- EISA Configuration Utility
- SCSI Select Utility Program
- System Programs
- Starting From the System Partition
- Starting From the Reference Diskette
- Main Menu Options
- Backup/ Restore System Programs Menu
- Set Configuration Menu
- Set Features Menu
- Test the Computer
- More Utilities Menu
- Advanced Diagnostic Program
- RAID Controller Utility
- Drive Information
- Formatting the Disks
- Defining a Hot- Spare Disk
- Creating a Disk Array
- Defining Logical Drives
- Setting the Write Policy
- Initializing the Array
- Backup/ Restoring the Configuration
- Chapter 4. Novell NetWare Installation
- ServerGuide Overview
- Starting ServerGuide
- Installing NetWare 4.1 with ServerGuide
- Installing NetWare 3.12 with Diskettes
- Hardware Requirements
- Software Requirements
- Information Requested at Time of Installation
- Installation Files
- Installation Procedure
- Installing NetWare 4.1 with the Original CD- ROM
- Hardware Requirements
- Software Requirements
- Installation Procedure
- NetFinity Services for NetWare
- System Requirements
- Installing NetFinity Services for NetWare
- The RAID Administration for NetWare Utility
- Installing the Utility
- Hard Disk Failure Simulation
- Simulating with a Hot Spare Drive
- Simulating without a Hot Spare Drive
- Chapter 5. Performance Tuning
- Appendix A. EISA Configuration File
- Appendix B. Hardware Compatibility, Device Driver, and Software Patch Information
- Appendix C. Configuring DOS CD-ROM Support
- List of Abbreviations
- Index
- Special Characters C
- Numerics
- A
- B
- D
- E
- F
- H
- M
- I
- N
- K
- L
- O
- P
- S
- Q
- R
- T
- U
- V
- W
- Z
- ITSO Technical Bulletin Evaluation RED000

Notes:
a. If only one hard disk has been assigned to the array, RAID level 0 will be
automatically assigned and the pop-up menu does not appear.
b. If only two hard disks are assigned to the array, RAID-5 is not selectable,
since at least three hard disk drives in an array are necessary to assign
RAID level 5 to one of the logical drives.
c. Define any RAID 5 logical drives first. This is because the first logical
drive seen will be the first RAID 5 drive created and will be assigned
drive letter c:. In this way, the operating system will be installed on a
RAID 5 drive.
d. The three RAID levels (0, 1 and 5) can be mixed in the same array
allowing the user to chose the optimum RAID level for each data type.
e. It is, however, not recommended to mix RAID 0 with the others levels if a
hot-spare drive is defined, since an automatic rebuild would not be
possible.
3. Assign the RAID level wanted and press Enter.
The logical drive size pop-up menu shows the space available in this array
for logical drives.
RAID 5 has been chosen in this example.
IBM RAID Controller Configuration Ver 2.12
Adapter in Slot 1
Enter Size Create/Delete Array
of Logical Ch 1 Ch 2
Drive, (MB) 1. Help Bay Bay
2. Define hot-spare drive Array Array
: 4300 3. Delete disk array
4. Create disk array 1 1
5. Define Logical drive
6. Format drive 2 2
7. Exit
3 HSP 3
4 ONL A 4
Array Arrays Log Size RAID Date
ID Size (MB) Drv (MB) Level Created 5 ONL A 5
A 6450 6 ONL A 6
7 7
Figure 65. RAID Configuration Program - RAID level Selection
4. Enter the size needed, within the limitation (for example 400).
5. Press Enter to confirm.
6. As shown in Figure 66 on page 111, information about the new logical drive
appears in the logical drive list.
110 NetWare Integration Guide