Specifications
56 Optimizing IBM Netfinity Servers for SAP R/3 and Windows NT
Figure 22. ASMA EISA Config File
a. Then select the EISA slot where the adapter is installed.
a. Press Esc to go back to the system configuration program main menu.
7. You do not have to change the Configuration Settings. The ASMA card is
automatically set to port 200h and interrupt 5 in the SCU.
2.12.2 SCU Settings for the NT Installation
Please check the following settings before you install Windows NT on the Netfinity
7000.
1. At the SCU program main menu screen, select Change Configuration
Settings.
2. Select System Board and press Enter. You will get a list with all configuration
settings for your system.
3. Ensure that the entry MP Spec Version is set to MP Spec V1.4.
Figure 23. BIOS Release and MP Level
4. Set the entry Secondary I/O APIC Control Option to Disable Secondary I/O
APIC and the entry PIC Interrupt Routing Mode to Route interrupts directly
to Local APIC.