Specifications

Configuring the Hardware and Installing Windows NT 55
2.12.1 SCU Settings for the ASMA Card
The Netfinity 7000 server requires a configuration file to configure ISA or EISA
adapters. The configuration file for the ASMA card is located on the System
CD-ROM and the System Configuration Diskette. The file is automatically
recognized through the SCU. The following steps depend on whether your
adapter was already entered in the SCU program or not.
1. At the SCU program main menu screen, select Add and Remove Boards.
2. Enter the Administrator password if defined; otherwise, press Esc.
3. You will see a list with the installed adapters in your system.
Figure 21 shows an Advanced System Management Adapter installed in EISA
Slot 1.
Figure 21. SCU Add and Remove Boards
4. If there a list entry with the IBM Advanced System Management Adapter in the
proper slot, press Esc to go back to the system configuration utility program
main menu.
5. If there a list entry with the ASMA card in the wrong slot, select the ASMA
card, press F7 and select the correct EISA slot where the adapter is installed.
Then press Esc to go back to the system configuration program main menu.
6. If there no entry for the ASMA card, do the following:
a. Press Insert to add an entry.
a. The ASMA EISA CFG-File is on the Netfinity System CD-ROM or the SCU
diskette and is shown in the following screen. Select in the list for EISA
CFG-Files the IBM Advanced System Management Adapter.