Specifications

52 Optimizing IBM Netfinity Servers for SAP R/3 and Windows NT
Figure 16. Main Menu ASMA Configuration Utility
4. Select 1. Configure Service Processor.
5. Select port address 200h and interrupt 5.
6. Check your settings by selecting 2. View Service Processor Configuration.
7. Select the port 200h again.
8. The adapter should respond with the configured interrupt and port address.
Figure 17. View Service Processor Configuration
9. Select 3. Update Service Processor to update the Service Processor
Firmware. The firmware upgrade will not work properly if the steps above were
not done successfully.
10.Follow the instructions to finish the update.
11.Then Select 5. Configure OS Watchdog Timer and select 1. Enable
WatchDog to enable the Watchdog timer.
12.Press F3 to exit the watchdog menu.
13.Select 6. Exit to leave the program.
14.Remove the diskette from the floppy disk drive and reboot the system.
If you are not able to complete the steps and configure the adapter or step 2,
View Service Processor Configuration, failed or you have any other problems with
the adapter, then you should reset the adapter and clear the configuration.
1. Power off and open the server.
2. Remove the adapter.