Specifications

Configuring the Hardware and Installing Windows NT 49
In the above command put the 7-digit serial number where the s’s are and the
3-digit feature number where the f’s are (along with the 8651 model number).
This information is located on the serial number label on the front cover.
17.At the next boot the POST will display the VPD banner with the information
you enter.
2.10.2 ServeRAID BIOS and Firmware Update
Two updates are available for the ServeRAID adapter: a BIOS and a firmware
update. The ServeRAID BIOS implements system functions and system
programs and is the interface to the system. The ServeRAID firmware on the
adapter controls the integrated IBM PowerPC 403 processor and implements the
RAID capabilities. The firmware is so to speak the operating system of the
adapter.
The BIOS and firmware updates are located on a single diskette.There are three
revisions of the ServeRAID adapters: the ServeRAID with one external SCSI
port, the PC Server 330 on-board single channel ServeRAID, and the ServeRAID
II with two external SCSI ports. The current valid BIOS and firmware versions
depend on your adapter but all adapters are provided with a flash utility. The flash
utility detects automatically your adapter revision and applies the right update.
Note: Only the ServeRAID II adapter is supported in the Netfinity 7000.
You can check your current installed BIOS and firmware version during the
system boot. In the following example, the BIOS is Version 2.70.04 and the
Firmware is Version 2.70.08.
Figure 15. BIOS and Firmware ServeRAID Adapter
Do the following steps to update your ServeRAID adapter.
Note: Read the README file on the ServeRAID and ServeRAID II
BIOS/Firmware flash update diskette.
A:>ADDVPD /B:sssssssss /M:8651fff