Specifications

Hard disk drive checkout
Message Action
Hard drive x removal detected
(level-critical; hard drive x has been
removed)
Information only; take action as appropriate.
Host built-in self test (BIST)
Message Action
Host fail
(level-informational; built-in self-test for the
host failed)
1. Reseat the microprocessor.
2. Replace the microprocessor.
Bus fault messages
Bus fault messages Message Action
Failure reading I2C device.
Check devices on bus 0.
1. If an I2C cable is connected between the Remote Supervisor
Adapter and the Remote Supervisor Adapter connector, reseat
the cable.
2. DIMMs.
3. System board.
Failure reading I2C device.
Check devices on bus 1.
1. Reseat the I2C cable between the operator information panel
and system board (connector CN6).
2. Operator information panel.
3. System board.
Failure reading I2C device.
Check devices on bus 2.
1. Reseat the cable between the system board and the power
supply (connector CN4).
2. Power supply.
3. System board.
Failure reading I2C device.
Check devices on bus 3.
1. Reseat the cable between the hard disk drive backplane and
connector on the system board.
2. Hard disk drive backplane.
3. System board.
Failure reading I2C device.
Check device on bus 4.
System board
Undetermined problems
Use the information in this section if the diagnostic tests did not diagnose the
failure, the devices list is incorrect, or the computer is inoperative.
Notes:
1. Damaged data in CMOS memory can cause undetermined problems.
2. Damaged data in BIOS code can cause undetermined problems.
Check the LEDs on all the power supplies. If the LEDs indicate that the power
supplies are working correctly, complete the following steps:
Symptom-to-FRU index 115