Specifications
Error code/symptom FRU/action
101, 102, 106
(System and processor error)
System board
151
(Real time clock error)
1. Run diagnostics.
2. Battery.
3. System board.
161
(Real time clock battery error)
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
162
(Device configuration error)
Note: Be sure to load the default settings
and any additional desired settings; then,
save the configuration.
1. Run the Configuration/Setup Utility program.
2. Battery.
3. Failing device.
4. System board.
163
(Real-time clock error)
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
164
(Memory configuration changed.)
1. Run the Configuration/Setup Utility program.
2. DIMM.
3. System board.
184
(Power-on password damaged)
1. Run the Configuration/Setup Utility program.
2. System board.
187
(VPD serial number not set.)
1. Set serial number in the Configuration/Setup Utility program.
2. System board.
189
(An attempt made to enter the system with
invalid passwords)
Run the Configuration/Setup Utility program.
201
(Memory test error.)
1. DIMM
2. System board
289
(DIMM disabled by the user or system.)
1. Run the Configuration/Setup Utility program.
2. DIMM.
3. System board.
301
(Keyboard or keyboard controller error)
1. Keyboard
2. System board
303
(Keyboard controller error)
System board
602
(Invalid diskette boot record)
1. Diskette
2. Diskette drive
3. Drive cable
4. System board
604
(Diskette drive error)
1. Run the Configuration/Setup Utility program and diagnostics.
2. Diskette drive.
3. Drive cable.
4. System board.
110 IBM IntelliStation M Pro Types 6220 and 6230: Hardware Maintenance Manual