Specifications
Error code/symptom FRU/action
020-XXX-000
(Failed PCI interface test.)
System board
030-XXX-00N
(Failed SCSI interface test.)
If N=0, system board; if N>0, SCSI adapter in slot N.
035-XXX-099
(No adapters were found.)
If adapter is installed re-check connection.
035-XXX-S99
(Failed RAID test on PCI slot S. S =
number of failing PCI slot.)
1. RAID adapter
2. Cable
3. System board
035-XXX-SNN
(s = number of failing PCI slot, nn = SCSI
ID of failing fixed disk.)
Hard disk drive with SCSI ID nn on RAID adapter in PCI slot s
035-253-S99
(RAID adapter initialization failure.)
1. ServeRAID
™
adapter in slot s is not configured properly. Obtain
the basic and extended configuration status and see the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable.
3. Adapter.
089-XXX-001
(Failed microprocessor test.)
1. Verify microprocessor 1 is installed an seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 1.
4. System board.
089-XXX-002
(Failed optional microprocessor test.)
1. Verify microprocessor 2 is installed an seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 2.
4. System board.
201-XXX-0NN
(Failed memory test.)
1. DIMM Location slots 1-2 where nn = DIMM location
Note: nn 1=DIMM 1; 2=DIMM 2
2. System board
201-XXX-999
(Multiple DIMM failure, see error text.)
1. See error text for failing DIMMs.
2. System board.
202-XXX-001
(Failed system cache test.)
1. Verify microprocessor 1 is installed and seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 1.
4. System board.
202-XXX-002
(Failed system cache test.)
1. Verify microprocessor 2 is installed and seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 2.
4. System board.
206-XXX-000
(Failed diskette drive test.)
1. Try test with another diskette.
2. Cable.
3. Diskette drive.
4. System board.
102 IBM IntelliStation M Pro Types 6220 and 6230: Hardware Maintenance Manual