Instruction manual

18
SCSI Card 2930U2 User’s Reference
Host Adapter SCSI Termination—Determines the termination
setting for the SCSI card. The default setting for both the
Ultra2-LVD/SE connector and Fast/Ultra-SE connector is
Automatic. We recommend that you leave this setting at
Automatic. If you want to manually change this setting for the
Fast/Ultra-SE connector, Table 2 lists the recommended
configurations.
Boot Device Options
Boot Target IDSpecifies the SCSI ID of your boot device.
Boot LUN Number—Specifies which LUN (Logical Unit
Numbers) to boot from on your boot device. Multiple LUN
Support must be enabled (see Advanced Configuration Options
on page 20).
Table 2. Host Adapter SCSI Termination Configuration
If SCSI Peripherals are Connected to These Fast/Ultra-SE
Connectors on the SCSI Card 2930U2… …Use this Setting
50-pin external connector only Enabled
50-pin internal connector only Enabled
50-pin internal and external connectors Disabled