Instruction manual
9
Troubleshooting
Common Error Messages
The following messages may appear at bootup:
“Device connected, but not ready”
The host received no answer when it requested data from an
installed SCSI peripheral.
■ Run SCSISelect and set the Send Start Unit Command to Ye s for
the particular SCSI peripheral ID.
■ Make sure the peripheral is set to spin up when the power is
switched on. The spin up option is typically set by a jumper.
(See the documentation for the peripheral.)
“Start unit request failed”
The SCSI Card BIOS was unable to send a Start Unit Command to
the peripheral.
■ Run SCSISelect and disable the Send Start Unit Command for
the peripheral.
“Time-out failure during...”
An unexpected time-out occurred.
■ Verify the SCSI bus is properly terminated.
■ Verify all cables are properly connected.
■ Try disconnecting the SCSI peripheral cables from the SCSI
card and then starting the computer. If the computer
successfully restarts, one of the SCSI peripherals may be
defective.