Product manual
31
3
Copy or download the
ptf
file to the
/tmp
directory. Use the
pkgadd
utility to install the I
2
O supplement by entering the command:
pkgadd –d /tmp/ptf7067e.s
4
Follow the on-screen prompts to install the SCO UnixWare I
2
O
supplement.
5
Shutdown and reboot the system.
Note:
When you reboot several warning messages may appear
and scroll off the screen quickly. These will not occur after
diskadd
is run and can be ignored.
6
Use the
diskadd
utility to add drives or arrays that are attached to a
SmartRAID V or SCSI RAID controller.
Run the
sdiconfig –l
utility in a terminal window. This will list all
controllers recognized by the operating system and any attached
devices. Use this listing to determine the proper ID to use for the
diskadd
utility.
The diskadd command to add devices on a secondary controller is:
diskadd cCbBtTdD