User`s guide

2-17
Storage Manager on ROM
The status condition is one of the following for attached devices:
The SCSI Capabilities section is a list of controller capabilities. A
check mark next to a feature indicates that the drive supports the
feature.
Negotiated Bus speed negotiated between the device and the
controller.
Transfer
Rate
Maximum transfer rate for negotiated bus speed and
transfer path (8-bit, 16-bit).
Dead Device failed to respond to controller commands. If the
device becomes available, it only changes status after
the system configuration is read or the host is
restarted.
Failed Drive failure occurred.
Impacted Performance degradation in response to server I/O
requests.
Missing Drive is physically missing or does not respond to
commands on the device bus.
Optimal Device is fully functional.
Uninitialized Drive is operational, but has been initialized as part of
an array.
Verify Verify operation is being performed on the array. I/O
performance is reduced.
Warning Imminent failure on a device with a S.M.A.R.T. failure
prediction.
Combined RAID SW-UG.book Page 17 Monday, September 9, 2002 1:25 PM