User`s guide

Table Of Contents
Appendix H: Technical Specifications 131
Environmental Specifications
Note: With a Battery Backup Unit (BBU), the ambient temperature should not exceed 40 °C
Note: Forced airflow is recommended.
DC Power Requirements
Current Requirements
Ambient temperature without forced airflow 0 °C to 40 °
C
Ambient temperature with forced airflow 0 °C to 55 °
C
Relative humidity 10% to 90%, noncondensing
Altitude Up to 3,000 meters
Bus Type Description Requirements
PCI, PCI-X, PCIe Ripple and noise 50 mV peak-to-peak (max)
PCI, PCI-X DC Voltage 5 V ± 5%, 3.3 V ± 10%
PCIe DC Voltage 3.3 V ± 9%, 12 V ± 8%
Adaptec Model Maximum Current (A)
Adaptec 3085 1.04 A @ 3.3 VDC; 0.98 A @ 12.0 VDC
Adaptec 3405 1.0 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec 3805 1.0 A @ 3.3 VDC; 1.0 A @ 12.0 VDC
Adaptec 31205 1.05 A @ 3.3 VDC; 1.48 A @ 12.0 VDC
Adaptec 31605 1.05 A @ 3.3 VDC; 1.48 A @ 12.0 VDC
Adaptec 4000 1.5 A @ 3.3 VDC; 0.75 A @ 5.0 VDC
Adaptec 4800SAS 1.4 A @ 3.3 VDC; 2.4 A @ 5.0 VDC
Adaptec 4805SAS 1.5 A @ 3.3 VDC; 1.3 A @ 12.0 VDC
Adaptec 2420SA
0.36 A @ 3.3 VDC; 2.4 A @ 5 VDC
Adaptec 2820SA 0.37 A @ 3.3 VDC; 2.4 A @ 5.0 VDC
Adaptec 2130SLP 2.5 A @ 3.3 VDC; 2 A @ 5.0 VDC
Adaptec 2230SLP 2.5 A @ 3.3 VDC; 2 A @ 5.0 VDC