User`s guide
Table Of Contents
- About This Guide
- Kit Contents and System Requirements
- About Your RAID Controller
- Standard RAID Controller Features
- Adding Enhanced Features
- Adding a Battery Backup Module
- Upgrading the Controller Firmware
- About the Adaptec 3085
- About the Adaptec 3405
- About the Adaptec 3805
- About the Adaptec 31205
- About the Adaptec 31605
- About the Adaptec 4000
- About the Adaptec 4800SAS
- About the Adaptec 4805SAS
- About the Adaptec 2420SA
- About the Adaptec 2820SA
- About the Adaptec 2130SLP
- About the Adaptec 2230SLP
- Getting Started
- Installing the Controller and Disk Drives
- Creating a Bootable Array
- Installing the Driver and an Operating System
- Installing the Driver on an Existing Operating System
- Managing Your Storage Space
- Solving Problems
- Introduction to Serial Attached SCSI
- Understanding RAID
- Using the Adaptec RAID Configuration Utility
- Using the Array Configuration Utility for DOS
- Using the Adaptec Flash Utility
- Adaptec Serial Controller LED and I2C Connector Reference
- Adaptec 2420SA Activity LED and I2C Connector Specification
- Adaptec 2820SA Activity LED and I2C Connector Specification
- Adaptec 3085 LED and I2C Connector Specification
- Adaptec 3405 LED and I2C Connector Specification
- Adaptec 3805 LED and I2C Connector Specification
- Adaptec 31205 LED and I2C Connector Specification
- Adaptec 31605 LED and I2C Connector Specification
- Adaptec 4800SAS LED and I2C Connector Specification
- Adaptec 4805SAS LED and I2C Connector Specification
- Safety Information
- Technical Specifications
- Index

Appendix E: Using the Adaptec Flash Utility ● 109
Verify
Compares the contents of each of the flash components on a RAID controller to the
corresponding image in a UFI file, and indicates whether they match. After using the VERIFY
command, you must restart the computer.
The command syntax for the VERIFY command is as follows:
AFU VERIFY [/C<Controller ID>] [/D <UFI File Path>]
This example shows a typical system response after a VERIFY command.
A:\> AFU VERIFY /C 0
Adaptec Flash Utility V4.0-0 B5749
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Reading flash image file (Build 5748)
Controller #0: Adaptec Adaptec 2820SA
ROM: Checksum: 797B [VALID] (Build 5748)
File: Checksum: 797B [VALID] (Build 5748)
Image Compares Correctly
Version
Displays version information about the flash components on a RAID controller. After using
the VERSION command, restart your computer.
The command syntax for the VERSION command is:
AFU VERSION [/C<Controller ID>]
This example displays version information about all supported RAID controllers.
A:\> AFU VERSION /C 0
Adaptec Flash Utility V4.0-0 B5749
(c)Adaptec Inc. 1999–2005. All Rights Reserved.
Version Information for Controller #0 (Adaptec Adaptec 2820SA)
ROM: Build 5748 [VALID] Fri Sep 27 13:28:40 EDT 2005
A:\> AFU VERSION /C ALL
Help
Displays a summary of AFU functions and command switches. For example:
A:\> AFU HELP
A:\> AFU /?