SAS, SATA, and SCSI RAID Controllers Installation and User’s Guide
● 2 Copyright ©2007 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035. Trademarks Adaptec, Adaptec Storage Manager, SCSISelect, SATASelect, SerialSelect and the Adaptec logo are trademarks of Adaptec, Inc.
● 3 Adaptec Customer Support If you have questions about installing or using your Adaptec product, check this document first—you will find answers to most of your questions. If you need further assistance, use the support options listed below. To expedite your service, have your computer in front of you. Technical Support Identification (TSID) Number ● Before contacting Technical Support, you need your unique 12-digit TSID number. The TSID number identifies your product and support status.
● 4 Limited 3-Year Hardware Warranty 1. Adaptec, Inc. (“Adaptec”) warrants to the purchaser of this product that it will be free from defects in material and workmanship for a period of three (3) years from the date of purchase.
● 5 Regulatory Compliance Statements Federal Communications Commission Radio Frequency Interference Statement WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.
Contents About This Guide What You Need to Know Before You Begin ................................................... 12 Terminology Used in this Guide ...................................................................... 12 How to Find More Information....................................................................... 12 Kit Contents and System Requirements Kit Contents ...................................................................................................... 14 System Requirements........
Contents ● 7 Getting Started Choosing a RAID Level..................................................................................... 31 Selecting Disk Drives ........................................................................................ 32 Disk Drives for SAS Controllers................................................................. 32 Disk Drives for SATA Controllers ............................................................. 32 Disk Drives for SCSI Controllers .........................
Contents ● 8 Installing with UnixWare ................................................................................. 53 Installing with VMware .................................................................................... 53 Installing with FreeBSD .................................................................................... 54 Installing the Driver on an Existing Operating System Before You Begin............................................................................................
Contents ● 9 Direct-attach Connections ......................................................................... 72 Backplane Connections .............................................................................. 72 SAS Expander Connections........................................................................ 73 How is SAS Different from Parallel SCSI? ....................................................... 74 Understanding RAID Understanding Drive Segments ........................................
Contents ● 10 About Playback Mode ................................................................................ 95 About Record Mode ................................................................................... 96 Creating the Script File Manually .............................................................. 96 Array Definition Block Keywords.............................................................. 97 Channel Definition Block Keywords—SCSI only...................................
1 About This Guide In this chapter... What You Need to Know Before You Begin .......................................................................... 12 Terminology Used in this Guide............................................................................................ 12 How to Find More Information ............................................................................................ 12 This Installation and User’s Guide explains how to install your Adaptec® RAID controller.
Chapter 1: About This Guide ● 12 What You Need to Know Before You Begin You should be familiar with computer hardware, data storage, RAID technology, and the input/output (I/O) technology—Small Computer System Interface (SCSI), SAS, or Serial ATA (SATA)—used by your controller. (For an introduction to SAS, see page 68.
Kit Contents and System Requirements 2 In this chapter... Kit Contents............................................................................................................................ 14 System Requirements ............................................................................................................. 14 This chapter lists the contents of your Adaptec RAID controller kit and the system requirements that must be met for you to successfully install and use your controller.
Chapter 2: Kit Contents and System Requirements ● 14 Kit Contents ● Adaptec RAID controller ● RAID Installation CD (bootable), including controller drivers, and this Guide ● Adaptec Storage Manager Installation CD (not bootable), including user guides for Adaptec Storage Manager and the ARCCONF command line utility ● Cables (Not all kits contain cables. If your kit does, the type and quantity vary—for cable information about your controller, visit the Adaptec Web site at www.adaptec.com.
About Your RAID Controller 3 In this chapter... About the Adaptec 3085......................................................................................................... 18 About the Adaptec 3405......................................................................................................... 19 About the Adaptec 3805......................................................................................................... 20 About the Adaptec 31205.............................................
Chapter 3: About Your RAID Controller ● 16 Standard RAID Controller Features ● Flash ROM for updates to controller firmware, BIOS, and the Adaptec RAID Configuration utility ● Disk drive hot-swapping ● Event logging and broadcasting including email and SNMP messages ● Multiple options for creating and managing RAID arrays—A full software application (Adaptec Storage Manager), a BIOS-based utility, a command line utility, and a DOS utility.
Chapter 3: About Your RAID Controller ● ● 17 Dual Drive Failure Protection (RAID 601)—A RAID 60 array is similar to a RAID 50 array except that it includes four independent sets of parity data instead of two. Adding Enhanced Features As your storage needs change, you can enhance data protection and improve performance by upgrading your Adaptec controller with extra features.
Chapter 3: About Your RAID Controller ● 18 About the Adaptec 3085 The Adaptec 3085 is a SAS RAID controller with these features: Diagnostic LEDs Board Power Supply Activity LEDs Alarm connector Drive Activity LED connectors for CN1/CN0 Mode 0 Flash connector CN1 Battery connector CN0 2 external SAS connectors PCIe x8 connector Mounting bracket Form Factor Low-profile MD2 Bus compatibility PCIe PCIe bus width x8 PCIe bus speed 2.
Chapter 3: About Your RAID Controller ● About the Adaptec 3405 The Adaptec 3405 is a SAS RAID controller with these features: Drive Activity LED connectors for CN0 Mode 0 Flash connector Aggregate Activity LED header for CN0 Battery connector 1 internal SAS connector CN0 I2C connector for CN0 Alarm connector Board power supply Drive Activity LEDs for CN0 Diagnostic LEDs PCIe x4 connector Mounting bracket Back side of Controller Form Factor Low-profile MD2 Bus compatibility PCIe PCIe bus width x4
Chapter 3: About Your RAID Controller About the Adaptec 3805 The Adaptec 3805 is a SAS RAID controller with these features: Aggregate Activity LED header for CN0 Drive Activity LED connectors for CN0/CN1 Mode 0 Flash connector CN1 Battery connector 2 internal SAS connectors Board power supply PCIe x4 connector CN0 I2C connector for CN0 Alarm connector Aggregate Activity LED header for CN1 I2C connector for CN1 Drive Activity LEDs Mounting bracket Diagnostic LEDs CN1 CN0 Back side of Controller F
Chapter 3: About Your RAID Controller ● 21 About the Adaptec 31205 The Adaptec 31205 is a SAS RAID controller with these features: I2C connector for CN2 I2C connector for CN1 I2C connector for CN0 Activity LED Phys and connectors E F Aggregate LED connectors C B A CN0 CN1 Alarm connector 3 internal SAS connectors CN2 Mode 0 Flash connector Battery connector PCIe x8 connector Mounting bracket Activity LED Phys and connectors F = CN2 E = CN1, CN0 Aggregate LED connectors C = CN2 B = CN1 A = CN0
Chapter 3: About Your RAID Controller ● 22 About the Adaptec 31605 The Adaptec 31605 is a SAS RAID controller with these features: I2C connector for CN3 Activity LED Phys and connectors F E Aggregate LED connectors D I2C connector for CN2 I2C connector for CN1 I2C connector for CN0 C B A CN0 CN1 Alarm connector 4 internal SAS connectors CN2 Mode 0 Flash connector CN3 Battery connector PCIe x8 connector Mounting bracket Activity LED Phys and connectors F = CN3, CN2 E = CN1, CN0 Aggregate LED c
Chapter 3: About Your RAID Controller About the Adaptec 4000 The Adaptec 4000 is a low-profile SAS Zero Channel RAID controller with these features: LED connector Mode 0 Flash connector I2C connector PCI-X connector Mounting bracket Form Factor Low-profile MD2 Bus compatibility PCI-X PCI-X bus width 64-bit PCI-X bus speed 133MHz Standard cache 128 MB DDR2 Connectors N/A RAID levels 0, 1, 1E, 10, 5, 5EE, 50,6, 60, JBOD Simple Volume Yes Disk Drives SATA, SATA II, SAS Maximum number o
Chapter 3: About Your RAID Controller ● 24 About the Adaptec 4800SAS The Adaptec 4800SAS is a SAS RAID controller with these features: Charge LED (for battery backup module) Alarm connector Mode 0 Flash connector Activity LED connector (top 2 left/right pins) Two 4-wide internal SAS connectors Mounting bracket 1 external SAS connector Battery connector PCI-X connector Diagnostic LED Activity LED Power LED Back side of Controller 1 Form factor 3/4 length Bus compatibility PCI-X, 3.
Chapter 3: About Your RAID Controller ● 25 About the Adaptec 4805SAS The Adaptec 4805SAS is a SAS RAID controller with these features: Charge LED (for battery backup module) Alarm connector Mode 0 Flash connector Activity LED connector (top 2 left/right pins) Two 4-wide internal SAS connectors Mounting bracket 1 external SAS connector Battery connector PCIe connector Diag LED Activity LED Power LED Activity LED Phy 76 5 4 32 1 0 Back side of Controller 1 Form Factor 3/4 length Bus Compatibili
Chapter 3: About Your RAID Controller ● 26 About the Adaptec 2420SA The Adaptec 2420SA is a SATA II RAID controller with these features: SATA ports 1 0 2 3 Activity LED connector LED connector Battery connector Mode 0 Flash connector I2C connector PCI-X jumper PCI-X connector Mounting bracket Activity LED Phy 3 2 1 3,3V LED IRQ LED 0 SUM Activity LED Charge LED (for battery backup module) Back side of Controller Form Factor Half-size Bus compatibility PCI-X, 3.
Chapter 3: About Your RAID Controller ● 27 About the Adaptec 2820SA The Adaptec 2820SA is a SATA II RAID controller with these features: SATA ports 0 1 2 7 6 5 4 3 Activity LED connector Mode 0 Flash connector LED connectors port 0-3 LED connectors port 0-3 Battery connector I2C connector PCI-X jumper PCI-X connector Mounting bracket 7 6 Activity LED Phy 5 4 SUM Activity LED 3 3,3V LED IRQ LED 2 1 0 Charge LED (for battery backup module) Diag LEDs Back side of Controller Form Facto
Chapter 3: About Your RAID Controller ● 28 About the Adaptec 2130SLP The Adaptec 2130SLP is a low-profile SCSI controller with these features: Mode 0 Flash connector Activity LED 1 internal HD SCSI connector Mounting bracket Battery connector 1 external VHDCI SCSI connector PCI/PCI-X connector Form Factor Low-profile MD2 Bus compatibility PCI-X, 3.
Chapter 3: About Your RAID Controller ● 29 About the Adaptec 2230SLP The Adaptec 2230SLP is a low-profile SCSI controller with these features: Mode 0 Flash connector Battery connector Activity LED 2 internal HD SCSI connectors 2 external VHDCI SCSI connectors PCI/PCI-X connector Mounting bracket Form Factor Low-profile MD2 Bus compatibility PCI-X, 3.
Getting Started 4 In this chapter... Choosing a RAID Level.......................................................................................................... 31 Selecting Disk Drives.............................................................................................................. 32 Selecting Cables ...................................................................................................................... 33 Installation Options ..............................................
Chapter 4: Getting Started ● 31 Choosing a RAID Level This section provides a brief overview of the RAID levels supported by your Adaptec RAID controller, including the minimum and maximum number of disk drives required by each. ● RAID 0 (Non-redundant Array)—Stripes data across multiple disk drives. Improved performance but no redundancy (see page 76). ● RAID 1 Array—Created from two disk drives where one disk drive is a mirror of the other (the same data is stored on each disk drive).
Chapter 4: Getting Started ● 32 Selecting Disk Drives When selecting disk drives for your RAID array, ensure that all the disk drives have the same performance level. You can use different-sized disk drives in the array, but the array will be limited to the capacity of the smallest and slowest disk drive. For more information, refer to the Adaptec Storage Manager User’s Guide for Internal RAID Storage or online Help.
Chapter 4: Getting Started ● 33 Selecting Cables This section describes the cable options and requirements for your Adaptec controller: ● For SAS cables, see this page. ● SATA cables, see page 34. ● SCSI cables, see page 35. SAS Cables You need one SAS cable for each disk drive you are connecting to your Adaptec SAS RAID controller. Depending on your requirements, you can use any of these cables: External cable (SFF-8470 to SFF-8470)—Connects to an external SAS enclosure.
Chapter 4: Getting Started ● 34 Internal mini-SAS to SATA fan-out (SFF-8087 to 4x SATA)—Connects to four SATA disk drives. External SAS (SFF-8088)—Connects to SAS or SATA disk drives on a backplane. Internal SAS (SFF-8484)—Connects to SAS or SATA disk drives on a backplane. Internal mini-SAS (SFF-8087)—Connects to SAS or SATA disk drives on a backplane. Cable connectors are keyed so that you can’t insert them incorrectly. Adaptec recommends using only Adaptec SAS cables.
Chapter 4: Getting Started ● 35 All SATA straight connector to straight connector cables have the same connectors, as shown in the following figure, and the connectors are keyed so that you can’t insert them incorrectly. Adaptec recommends using only Adaptec SATA cables. For more information or to purchase cables, visit the Adaptec Web site at www.adaptec.com. SCSI Cables Depending on your requirements, you may need one or two internal cables. You may also need one external SCSI cable.
Chapter 4: Getting Started ● 4 Install your operating system and the controller driver (see page 48.) 5 Install Adaptec Storage Manager and begin to manage your data storage (see page 61). 36 Note: Currently, Adaptec Storage Manager is not supported on FreeBSD. To create and manage arrays, use the ARC utility. See page 63 for more information. Installing on an Existing Operating System 1 Install and connect your controller and internal disk drives (see page 37).
Installing the Controller and Disk Drives 5 In this chapter... Before You Begin .................................................................................................................... 38 Installing the Controller......................................................................................................... 38 Connecting Disk Drives to SAS RAID Controllers............................................................... 39 Connecting Disk Drives to SATA RAID Controllers ..............
Chapter 5: Installing the Controller and Disk Drives ● 38 Before You Begin ● Read Safety Information on page 129. ● Familiarize yourself with your Adaptec RAID controller’s physical features and the RAID levels that it supports (see page 15). ● Ensure you have the right quantity of disk drives for the RAID level you want to use for your arrays (see page 32). ● Ensure that you have the proper cables for your controller and disk drives (see page 33).
Chapter 5: Installing the Controller and Disk Drives ● 39 6 Optional—Connect your RAID controller’s I2C connector (not available on all models) to an I2C connector on an internal backplane or enclosure, using an I2C cable. For more connection details, see About Your RAID Controller on page 15. 7 Prepare and install your internal disk drives, following the instructions for your type of controller: ● For SAS RAID controllers, see page 39. ● For SATA RAID controllers, see page 41.
Chapter 5: Installing the Controller and Disk Drives 2 ● 40 Use internal SAS or mini-SAS cables to attach the disk drives to the controller.
Chapter 5: Installing the Controller and Disk Drives ● 41 Disk drives on backplane Controller connected to backplane with Internal mini-SAS (SFF-8087) Disk drives on backplane External SAS cable connecting to a drive bay Controller connected to backplane with multi-lane cable (SFF-8484) 3 When all internal disk drives have been installed and connected, close your computer cabinet, reattach the power cord, then continue with Connecting External Devices on page 42.
Chapter 5: Installing the Controller and Disk Drives 2 ● 42 Install a terminator (or enable termination) on the disk drive at the end of each cable, or the end of the cable itself. Remove any terminators (or disable termination) on disk drives between the ends of each cable. Install your SCSI disk drives, following the instructions in your system’s documentation. 3 If space inside your computer cabinet is limited, connect your disk drives to the SCSI cable before installing them.
Creating a Bootable Array 6 In this chapter... Setting the Boot Controller.................................................................................................... 44 Creating an Array ................................................................................................................... 44 Making Your Array Bootable .................................................................................................
Chapter 6: Creating a Bootable Array ● 44 Setting the Boot Controller Note: If your system won’t contain more than one bootable controller, skip to the next section, Creating an Array. Your Adaptec RAID controller supports bootable disk drives and bootable arrays. To enable your system to boot from either a disk drive or an array connected to your controller: 1 Enter the system setup. 2 Navigate to the drive boot sequence. 3 Move the boot controller to the top of the list.
Chapter 6: Creating a Bootable Array ● 45 4 Select Initialize Drives, then press Enter. 5 Select at least three disk drives for the array, press Insert for each selected disk drive, then press Enter. ! Caution: During initialization, all data is deleted from the disk. Before continuing, back up any data you want to keep. 6 Press Y, then press Enter. The selected disk drives are initialized, then the ACU screen appears. 7 Select Create Array, then press Enter.
Chapter 6: Creating a Bootable Array ● 46 Creating an Array with Adaptec Storage Manager This section describes how to use the Adaptec Storage Manager configuration wizard to build a RAID 5 array. Note: You will need the Adaptec Storage Manager Installation CD to complete this task. To create a RAID 5 array: 1 Insert the Adaptec Storage Manager Installation CD into your CD drive, then restart your computer. 2 When prompted, select the language you want, then press Enter.
Chapter 6: Creating a Bootable Array 7 ● 47 Review the information that is displayed. Note: In DAS environments, Adaptec Storage Manager uses the term logical drives when referring to arrays (see page 12). In this example, Adaptec Storage Manager has used thirteen equal-sized disk drives to automatically create one logical drive with RAID 5 and a hot spare.
Installing the Driver and an Operating System 7 In this chapter... Before You Begin .................................................................................................................... 49 Creating a Driver Disk ........................................................................................................... 49 Installing with Windows ........................................................................................................ 50 Installing with Red Hat Linux .........
Chapter 7: Installing the Driver and an Operating System ● 49 Before You Begin ● Install and connect your Adaptec RAID controller and internal disk drives (see page 37). ● Create a bootable array (see page 43). ● Create a driver disk (see the following section). Note: For up-to-date operating system version support, visit the Adaptec Web Site at www.adaptec.com. From the main menu select Support>Knowledgebase>Find Answers.
Chapter 7: Installing the Driver and an Operating System ● For OpenServer, see page 52. ● For Solaris, see page 52 ● For UnixWare, see page 53. ● For VMware, see page 53. ● For FreeBSD, see page 54. ● 50 Installing with Windows Note: You will need your Windows Installation CD to complete this task. To install the Adaptec RAID controller driver while installing Windows: 1 Insert your Windows CD, then restart the computer. 2 Follow the on-screen instructions to begin the Windows installation.
Chapter 7: Installing the Driver and an Operating System ● 51 Installing with SUSE Linux To install the Adaptec RAID controller driver while installing SUSE Linux: 1 Insert the first SUSE Installation CD. 2 Restart your computer. 3 When the SUSE installation selection screen appears, choose the type of installation you want, then press the F6 key to indicate the use of a driver disk. (If F6 is not shown on the screen, you may have an older version of SUSE; press the Alt key instead.
Chapter 7: Installing the Driver and an Operating System 8 ● 52 From the lower window menu, select Continue, then press Enter. If the driver installation process fails, the server console is displayed so you can see the cause of the failure. To modify disk partitions, apply hot fixes, or perform volume maintenance, refer to your NetWare documentation. 9 Continue with Managing Your Storage Space on page 61.
Chapter 7: Installing the Driver and an Operating System ● 53 Installing with UnixWare Note: You will need your UnixWare Installation CD to complete this task. To install the driver when installing UnixWare: 1 Insert the UnixWare Installation CD. 2 Restart your computer. 3 Follow the on-screen instructions to begin the UnixWare installation. 4 When prompted to load more HBA drivers, insert the driver disk, then select Yes. (To load more HBA drivers, repeat this step.
Chapter 7: Installing the Driver and an Operating System ● 54 Installing with FreeBSD Note: You will need your FreeBSD Installation CD to complete this task. To install the driver when installing FreeBSD: 1 Insert the FreeBSD Installation CD. 2 Restart your computer. 3 When the FreeBSD start screen opens, select 6 to escape to loader prompt. 4 Type load kernel. 5 Insert the driver floppy disk. 6 Type load disk0:aacu.ko.
Installing the Driver on an Existing Operating System 8 In this chapter... Before You Begin .................................................................................................................... 56 Creating a Driver Disk ........................................................................................................... 56 Installing on Windows ...........................................................................................................
Chapter 8: Installing the Driver on an Existing Operating System ● 56 Before You Begin Before you begin, install and connect your Adaptec RAID controller and internal disk drives (see page 37). You must also create a driver disk (see page 49) before you begin installing the controller driver. Note: For up-to-date operating system version support, visit the Adaptec Web Site at www.adaptec.com. From the main menu select Support>Knowledgebase>Find Answers.
Chapter 8: Installing the Driver on an Existing Operating System ● For VMware, see page 59. ● For FreeBSD, see page 60 ● 57 Installing on Windows To install the driver on Windows: 1 Start or restart Windows. The Found New Hardware Wizard opens and searches for the driver. 2 Insert the driver disk, select Floppy drive, then click Next. 3 Click Next, then click Next again. 4 Follow the on-screen instructions to complete the driver installation.
Chapter 8: Installing the Driver on an Existing Operating System 6 At the Additional Driver Options menu, select Modify, then press Enter. 7 If aacraid.ham has already been detected, delete it. 8 At the Driver Name menu, press the Insert key. 9 Insert the driver disk, press the Insert key, then press F3. ● 58 10 At the A:\ prompt, press Enter. The driver installs. 11 At the Additional Driver Option menu, select Return to driver summary, then press Enter.
Chapter 8: Installing the Driver on an Existing Operating System ● 59 Installing on UnixWare To install the driver on UnixWare: 1 Start your computer, then insert the driver disk. 2 Begin the driver package installer: pkgadd -d diskette1 3 At the installer prompt, type go. 4 Select 1 for the aacraid package. 5 When the installation is complete, select q to quit the installer. 6 Reboot your computer and remove the driver disk. 7 Continue with Managing Your Storage Space on page 61.
Chapter 8: Installing the Driver on an Existing Operating System Installing on FreeBSD To install the driver on FreeBSD: 1 Start your computer. 2 Insert and mount the driver disk: mount -t msdos /dev/fd0 /mnt 3 Copy the driver package to the /tmp directory: cp /mnt/aac-02.00.00-x.tgz /tmp 4 Install the driver package: pkg_add /tmp/aac-02.00.00-x.tgz 5 Reboot your computer, then remove the driver disk. Note: Currently, Adaptec Storage Manager is not supported on FreeBSD.
Managing Your Storage Space 9 In this chapter... About Adaptec Storage Manager........................................................................................... 62 About the Adaptec RAID Controller Configuration Utility ................................................ 62 About the Adaptec RAID Configuration Utility................................................................... 63 About the Adaptec Flash Utility .................................................................................
Chapter 9: Managing Your Storage Space ● 62 About Adaptec Storage Manager Note: Currently, Adaptec Storage Manager is not supported on FreeBSD. To create and manage arrays, use theARC utility. See page 63 for more information. Adaptec Storage Manager is a full-featured software application that helps you build a storage space for your online data, using Adaptec RAID controllers and disk drives.
Chapter 9: Managing Your Storage Space ● 63 About the Adaptec RAID Configuration Utility The Adaptec RAID Configuration (ARC) utility is a BIOS-based utility that you can use to create and manage controllers, disk drives and other devices, and arrays. The ARC utility comprises these tools: ● Array Configuration Utility (ACU)—For creating and managing arrays, and initializing and rescanning disk drives. (ACU for DOS is also available. See page 93.
Solving Problems 10 In this chapter... Troubleshooting Checklist ..................................................................................................... 65 Silencing the Alarm ................................................................................................................ 65 Recovering from a Disk Drive Failure ................................................................................... 65 Resetting the Controller.......................................................
Chapter 10: Solving Problems ● 65 Troubleshooting Checklist If you encounter difficulties installing or using your Adaptec RAID controller, check these items first: ● With your computer powered off, check the connections to each disk drive, power supply, LED connector, and so on. Try disconnecting and reconnecting disk drives from the Adaptec RAID controller. ● Check that your Adaptec RAID controller is installed in a compatible expansion slot (PCI, PCI-X, or PCIe).
Chapter 10: Solving Problems ● 66 Failed Disk Drive Protected by a Hot Spare When an array is protected by a hot spare, if a disk drive in that array fails the hot spare is automatically incorporated into the array and takes over for the failed drive. To recover from the failure: 1 Remove and replace the failed disk drive (following manufacturer’s instructions).
Chapter 10: Solving Problems ● 67 Multiple Failures in the Same Array Except in RAID 6 and RAID 60 arrays (see page 75), if more than one disk drive fails at the same time in the same array, the data can’t be recovered. Correct the cause of the failure or replace the failed disk drives. Then, restore your data (if available). Note: In some instances, RAID 10 and RAID 50 arrays may survive multiple disk drive failures, depending on which disk drives fail.
Introduction to Serial Attached SCSI A In this appendix... Terminology Used in This Chapter ....................................................................................... 69 What is SAS? ........................................................................................................................... 69 How Do SAS Devices Communicate? ................................................................................... 70 What’s a Phy? .....................................................
Appendix A: Introduction to Serial Attached SCSI ● 69 Terminology Used in This Chapter For convenience, SAS HBAs and SAS RAID controllers are referred to generically in this chapter as SAS cards. HBAs, RAID controllers, disk drives, and external disk drive enclosures are referred to as end devices and expanders are referred to as expander devices. For convenience, this chapter refers to end devices and expander devices collectively as SAS devices.
Appendix A: Introduction to Serial Attached SCSI ● 70 How Do SAS Devices Communicate? SAS devices communicate with each other through links. A link is a physical connection between two phys. As shown in the following figure, SAS devices contain ports (see page 71), ports contain phys, and each phy contains one transmitter and one receiver—one transceiver. A phy can belong to one port only.
Appendix A: Introduction to Serial Attached SCSI ● 71 What’s a SAS Port? Note: Because the physical link between SAS devices is from phy to phy, rather than port to port, a “port” is more of a virtual concept, different from what is normally considered a port on other types of RAID controllers and storage devices. A port is one or more phys. A narrow port contains one phy. A wide port typically contains four phys.
Appendix A: Introduction to Serial Attached SCSI ● 72 How are Disk Drives Identified in SAS? In the BIOS and in the management utilities (see Identifying Disk Drives on page 91), disk drives are identified in the following formats: ● CNX:DevY = Device Y is attached to Connector X (see Direct-attach Connections below for more information) ● BoxX:SlotX = Enclosure X is attached to a disk drive in Slot X (see Backplane Connections below for more information) ● ExpX:PhyX = Expander X is attached to Phy
Appendix A: Introduction to Serial Attached SCSI ● 73 Some backplanes support daisy-chain expansion to other backplanes. For example, you can daisy-chain (connect one to the next) up to nine Adaptec S50 enclosures to a single SAS card in a host system. SAS Expander Connections A SAS expander device literally expands the number of end devices that you can connect together.
Appendix A: Introduction to Serial Attached SCSI ● 74 How is SAS Different from Parallel SCSI? In summary, although SAS and parallel SCSI both use the SCSI command set, how they move data from one place to another is very different. To support point-to-point serial data transport, SAS introduces new types of connectors, cables, connection options, and terminology. Generally speaking, SAS is faster and more flexible than parallel SCSI, and provides more options for building your storage space.
Understanding RAID B In this appendix... Understanding Drive Segments............................................................................................. 76 Non-redundant Arrays (RAID 0) .......................................................................................... 76 RAID 1 Arrays ........................................................................................................................ 77 RAID 1 Enhanced Arrays...........................................................
Appendix B: Understanding RAID ● 76 Understanding Drive Segments A drive segment is a disk drive or portion of a disk drive that is used to create an array. A disk drive can include both RAID segments (segments that are part of an array) and available segments. Each segment can be part of only one logical device at a time. If a disk drive is not part of any logical device, the entire disk is an available segment.
Appendix B: Understanding RAID ● 77 RAID 1 Arrays A RAID 1 array is built from two disk drives, where one disk drive is a mirror of the other (the same data is stored on each disk drive). Compared to independent disk drives, RAID 1 arrays provide improved performance, with twice the read rate and an equal write rate of single disks. However, capacity is only 50 percent of independent disk drives.
Appendix B: Understanding RAID ● 78 RAID 10 Arrays A RAID 10 array is built from two or more equal-sized RAID 1 arrays. Data in a RAID 10 array is both striped and mirrored. Mirroring provides data protection, and striping improves performance. Drive segment size is limited to the size of the smallest disk drive in the array.
Appendix B: Understanding RAID ● 79 RAID 5 Arrays A RAID 5 array is built from a minimum of three disk drives, and uses data striping and parity data to provide redundancy. Parity data provides data protection, and striping improves performance. Parity data is an error-correcting redundancy that’s used to re-create data if a disk drive fails. In RAID 5 arrays, parity data (represented by Ps in the next figure) is striped evenly across the disk drives with the stored data.
Appendix B: Understanding RAID ● 80 RAID 5EE Arrays A RAID 5EE array—also known as a hot space—is similar to a RAID 5 array except that it includes a distributed spare drive and must be built from a minimum of four disk drives. Unlike a hot spare, a distributed spare is striped evenly across the disk drives with the stored data and parity data, and can’t be shared with other logical disk drives. A distributed spare improves the speed at which the array is rebuilt following a disk drive failure.
Appendix B: Understanding RAID ● 81 RAID 50 Arrays A RAID 50 array is built from six to forty-eight disk drives configured as two or more RAID 5 arrays, and stripes stored data and parity data across all disk drives in both RAID 5 arrays. (For more information, see RAID 5 Arrays on page 79.) Note: Because they support four disk drives only, the Adaptec 2420SA RAID controller can’t support RAID 50 arrays. The parity data provides data protection, and striping improves performance.
Appendix B: Understanding RAID ● 82 RAID 6 Arrays A RAID 6 array—also known as dual drive failure protection—is similar to a RAID 5 array because it uses data striping and parity data to provide redundancy. However, RAID 6 arrays include two independent sets of parity data instead of one. Both sets of parity data are striped separately across all disk drives in the array. RAID 6 arrays provide extra protection for your data because they can recover from two simultaneous disk drive failures.
Appendix B: Understanding RAID ● 83 Selecting the Best RAID Level Use this table to select the RAID levels that are most appropriate for the logical drives on your storage space, based on the number of available disk drives and your requirements for performance and reliability.
Using the Adaptec RAID Configuration Utility C In this appendix... Introduction to the ARC Utility ............................................................................................ 85 Running the ARC Utility........................................................................................................ 85 Using the ACU to Create and Manage Arrays ...................................................................... 85 Using the -Select Utility to Modify Controller Settings ...........
Appendix C: Using the Adaptec RAID Configuration Utility ● 85 Introduction to the ARC Utility The ARC utility comprises these tools: ● The Array Configuration Utility (ACU)—For creating and managing arrays, and initializing and rescanning disk drives (see page 85). Note: Also available—ACU for DOS. See page 93. ● A -Select Utility—SerialSelect, SATASelect, or SCSISelect, for modifying your controller and disk drive settings (see page 87).
Appendix C: Using the Adaptec RAID Configuration Utility ● 86 Managing Existing Arrays To view or modify existing arrays, select Manage Arrays from the main ACU menu. From the Manage Arrays menu, you can: ● View the properties of an array. Note: Failed drives are displayed in a different text color. ● Make an array bootable (see Creating Bootable Arrays on page 86). ● Assign or remove hot spares. ● Delete an array.
Appendix C: Using the Adaptec RAID Configuration Utility ● 87 Secure Erasing Disk Drives When you perform a secure erase on a disk drive, all data on that disk drive is completely and irretrievably eradicated. Secure erase performs three distinct writing passes to the disk drive being erased—it does not just write zeros. Performing a secure erase takes up to six times longer than clearing (or zeroing) a disk drive.
Appendix C: Using the Adaptec RAID Configuration Utility ● 88 Modifying Your Controller’s Configuration Note: Default controller settings are suitable for most computers. Adaptec recommends that you do not change the default setting. To modify your controller’s settings, select Controller Configuration from the main -Select utility menu. The following table lists controller configuration options. Some options may not be available for your controller.
Appendix C: Using the Adaptec RAID Configuration Utility ● 89 SAS-specific Controller Settings In addition to the general settings listed on page 88, your Adaptec SAS controller has SASspecific settings that can be modified if required. (For more information about SAS, see page 68.) Note: This feature is not available with the Adaptec 31205 or Adaptec 31605 controllers. To modify SAS-specific settings, select PHY Configuration from the SerialSelect main menu.
Appendix C: Using the Adaptec RAID Configuration Utility ● 90 SCSI-specific Controller Settings In addition to the general settings listed on page 88, your Adaptec SCSI controller has SCSIspecific settings that can be modified if required. To modify SCSI-specific settings, select SCSI Configuration from the SCSISelect main menu. SCSI Device Settings You can use SCSISelect to modify some of the settings on the SCSI devices connected to your SCSI controller.
Appendix C: Using the Adaptec RAID Configuration Utility ● 91 Formatting and Verifying Disk Drives You can use the disk utilities to low-level format or verify your disk drives. (New disk drives are low-level formatted at the factory and do not need to be low-level formatted again.) ! Caution: Before you format a disk drive, back up all data. Formatting destroys all data on a disk drive. To format or verify a disk drive: 1 Start the ARC utility (see page 85).
Appendix C: Using the Adaptec RAID Configuration Utility ● 92 The location information of a disk drive is determined by three types of connections: ● Direct attached drives—The connection is determined by the cable connected to a device, for example CN1 (connector 1) is connected to DEV1 (device 1). For more information, see Direct-attach Connections on page 72. ● Storage Enclosure Processor (SEP) managed devices—The connection is determined by an active backplane.
Using the Array Configuration Utility for DOS D In this appendix... Getting Started ....................................................................................................................... 94 Working in the ACU Using Menus........................................................................................ 94 Running the ACU Using Scripts............................................................................................
Appendix D: Using the Array Configuration Utility for DOS ● 94 Getting Started Note: You need a bootable floppy disk to complete this task. The ACU for DOS runs from a floppy disk which you can create using the RAID Installation CD that came in your Adaptec RAID controller kit. To create the ACU floppy disk: 1 Insert your RAID Installation CD into the CD drive, then browse to this file: packages/firmware/controllermodel/acu.exe Where controllermodel is the model number of your Adaptec RAID controller.
Appendix D: Using the Array Configuration Utility for DOS ● 95 Running the ACU Using Scripts To work in the ACU using scripts: 1 Insert the ACU floppy disk (see page 94), then start or restart your computer. The computer boots to the DOS command line. 2 Type ACU on the command line, specify a script file, and specify either the /P or /R switches listed in the following table. (Don’t specify both.) You may also add one or both of the optional switches. Note: Command line syntax is not case sensitive.
Appendix D: Using the Array Configuration Utility for DOS ● 96 About Record Mode Note: You can also create a script file manually (see the following section). In Record Mode, the ACU writes a RAID controller’s existing array configuration to a specified script file, which lets you create the same configuration by running the ACU in Playback Mode (/P switch) with the resulting script. You can only record one RAID controller at a time with Record Mode.
Appendix D: Using the Array Configuration Utility for DOS ● 97 Array Definition Block Keywords The array definition block always begins with the keyword Array and ends with the keyword End. The other required array definition keywords are Drives and Type. Array definition keywords and descriptions are listed in this table. Keyword Required? Description Array Yes Indicates the start of an array definition block. No default. See page 97.
Appendix D: Using the Array Configuration Utility for DOS ● 98 End Keyword End is a required keyword, indicating the end of the block. HotspareDrives Keyword Hotspare Drives is an optional keyword, specifying the hot spares to assign to the array. The syntax for listing hot spares is the same as the Drives Keyword on page 97. If Hotspare Drives is not specified, no hot spares are assigned to the array.
Appendix D: Using the Array Configuration Utility for DOS ● 99 Method Keyword Method is an optional keyword, indicating which method to use when creating a redundant (RAID 1, 1E, 10, 5, 5EE, 50, 6 and 60) array. Possible values: ● Build (the default)—Perform a Build/Verify process on the array. Takes longer than Clear, but allows you to begin using the array immediately. ● Clear—Clear the array.
Appendix D: Using the Array Configuration Utility for DOS ● 100 Type Keyword Type is a required keyword, indicating the array type. There is no default value. The possible values: Volume, RAID0, RAID1, RAID5, RAID10, or RAID50. Depending on the RAID levels supported by your RAID controller, additional possible values are: RAID1E, RAID5EE, RAID6, RAID60.
Appendix D: Using the Array Configuration Utility for DOS ● 101 ControllerID Keyword ControllerID is an optional keyword to change the SCSI ID of the controller. Normally, the SCSI controller is assigned SCSI ID 7 on each of its channels. You can specify any ID value between 0 and 7. ! Caution: Do not change the SCSI ID of the controller unless directed to do so by Adaptec Technical Support. For example: ControllerID=7 End Keyword End is a required keyword, indicating the end of the block.
Appendix D: Using the Array Configuration Utility for DOS ● 102 Code Description 19 Unable to read SATA port parameters. Unable to read SCSI channel parameters. 20 Unable to write SATA port parameters. Unable to write SCSI channel parameters. 21 Failed in getting kernel version. Unknown product ID. 22 Kernel timeout in writing command. 23 No RAID channels available 24 Error: wrong stripe size in creating array - script mode.
Appendix D: Using the Array Configuration Utility for DOS ● 103 # Clear the array (don’t build/verify it) Method=Clear # Don’t wait for clear to complete Wait=No # Use drives 0, 1, 2 Drives=0:0:0, 0:1:0, 0:2:0 End Sample Script for SATA Controllers This is a sample ACU file that will initialize all disk drives connected to the SATA controller and create a RAID 5 array with the disk drives on ports 0, 1, and 2.
Using the Adaptec Flash Utility E In this appendix... System Requirements ........................................................................................................... 105 Before You Begin .................................................................................................................. 105 Running the Menu-based AFU............................................................................................ 106 Running the AFU from the Command Line...........................
Appendix E: Using the Adaptec Flash Utility ● 105 System Requirements ● MS–DOS version 5.0 or later. Note: You can’t run the AFU from a DOS command prompt window under any version of Windows. ● At least 8 MB of extended memory. Compatibility Notes ● Supports HIMEM.SYS; compatible with other DOS drivers running under HIMEM.SYS (for example, SMARTDRV.SYS and SETVER.SYS). ● Does not support DOS extenders installed in memory, such as EMM386.SYS and DOS4GW.
Appendix E: Using the Adaptec Flash Utility ● 106 Creating the Firmware Floppy Disks Note: You will need at least two bootable MS-DOS floppy disks to complete this task. You can’t create a bootable floppy disk using Windows 2000. To create the firmware floppy disks: 1 Create a bootable MS–DOS floppy disk and copy these files to it: ● AFU.exe ● Axxxx01.ufi where xxx is the model number of your controller. Note: Most controller model numbers have a suffix (for example Adaptec 4800SAS).
Appendix E: Using the Adaptec Flash Utility 6 ● 107 Complete the flash operation and restart your computer before trying to use the RAID controller again. (You can not use your RAID controller while you are updating its flash.) Running the AFU from the Command Line Note: You can also run a menu-based AFU (see page 106). To run the AFU from the command line: 1 Power off your computer, insert the first AFU floppy disk, then power on your computer.
Appendix E: Using the Adaptec Flash Utility ● 108 These switches are available: ● /C —One or more RAID controller IDs representing the set of RAID controllers on which to perform the specified command. The default is 0; if the computer has multiple RAID controllers, the AFU defaults to controller 0 unless you specify otherwise.
Appendix E: Using the Adaptec Flash Utility ● 109 Verify Compares the contents of each of the flash components on a RAID controller to the corresponding image in a UFI file, and indicates whether they match. After using the VERIFY command, you must restart the computer. The command syntax for the VERIFY command is as follows: AFU VERIFY [/C] [/D ] This example shows a typical system response after a VERIFY command. A:\> AFU VERIFY /C 0 Adaptec Flash Utility V4.
Appendix E: Using the Adaptec Flash Utility ● 110 Updating the Flash Using the AFU Command Line 1 Create the firmware floppy disks (see page 106). 2 Power off your computer, insert the first AFU floppy disk, then power on your computer. If your computer isn’t set up to boot from the bootable floppy disk, enter the system setup utility to change the setting.
Adaptec Serial Controller LED and I2C Connector Reference F In this appendix... Adaptec 2420SA Activity LED and I2C Connector Specification...................................... 112 Adaptec 2820SA Activity LED and I2C Connector Specification...................................... 113 Adaptec 3085 LED and I2C Connector Specification ........................................................ 114 Adaptec 3405 LED and I2C Connector Specification ........................................................
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 112 Adaptec 2420SA Activity LED and I2C Connector Specification 2169300JA-R AAR-2420SA/JA ROHS KIT 2169300-R AAR-2420SA ROHS KIT 2169400-R AAR-2420SA/256MB ROHS SGL ● Adaptec 2420SA LED Board Connector: Molex 53398-0490 or equivalent ● LED Mating Cable Connector: Molex 51021-0400 or equivalent J11: Pin Number Signal Description 1 LP0- PORT 0 Cathode 2 LP1- PORT 1 Cathode 3 LP2- PORT 2 Cathode 4 LP3- PORT 3 Cat
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 113 Adaptec 2820SA Activity LED and I2C Connector Specification 2169900JA-R AAR-2820SA/JA RoHS KIT 2169900-R AAR-2820SA RoHS KIT 2170000-R AAR-2820SA/256MB RoHS SGL ● Adaptec 2820SA LED Board Connector #1: Molex 53398-0490 or equivalent ● LED Mating Cable Connector #1: Molex 51021-0400 or equivalent J11: Pin Number Signal Description 1 LP0- PORT 0 Cathode 2 LP1- PORT 1 Cathode 3 LP2- PORT 2 Cathode 4 LP3- PORT
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● J14: Pin Number Signal Description 1 IIC_EM_DATA I2C Data 2 GND Ground 3 IIC_EM_CLK I2C Clock Adaptec 3085 LED and I2C Connector Specification 2251600-R ASR-3085 RoHS Kit 2251600JA-R ASR-3085/JA RoHS Kit ● Adaptec 3085 LED Board Connector: Molex 10-89-7162 2.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● ● 115 LED Mating Cable Connector: Molex 22-55-2081 or equivalent. J10: J10 Pin Number Signal Description 22-55-2081 Pin Number 9 +3.3V CONNECTOR J5-PORT0 Anode 2 10 ACT0_7_LED_L (7) CONNECTOR J5-PORT0 Cathode 1 11 +3.3V CONNECTOR J5-PORT1 Anode 4 12 ACT0_7_LED_L (6) CONNECTOR J5-PORT1 Cathode 3 13 +3.3V CONNECTOR J5-PORT2 Anode 6 14 ACT0_7_LED_L (5) CONNECTOR J5-PORT2 Cathode 5 15 +3.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 116 Pin Number Signal I2C Description SGPIO Description B11 CONTROLLER_TYPEB_BUF SB6 – Controller Type SB6 – Controller Type A8 BACKPLANE_TYPEB SB7 – Backplane Type SB7 – Backplane Type Adaptec 3805 LED and I2C Connector Specification 2252100-R ASR-3805 RoHS Kit 2252100JA-R ASR-3805/JA RoHS Kit 2252200-R ASR-3805 RoHS Single 2252300-R ASR-3805/256MB RoHS Single ● Adaptec 3805 LED Board Connector: Molex 10-89-7162
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 117 ● Adaptec 3805 Aggregate Activity LED Board Connector: Molex 22-28-8022 2.54mm 1x2 RA Header or equivalent ● LED Mating Cable Connector: Molex 50-57-9002 or equivalent J12: Pin Number Signal Description 2 AGGREGATE4_7_L Aggregate Cathode – Connector J5 Ports 0-3 1 +3.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 118 SFF-8087 Connector J5: Pin Number Signal I2C Description SGPIO Description B8 SB0_CONB SB0 - 2W_SCL SB0 - SClock B9 SB1_CONB SB1- 2W_SDA SB1- SLoad B10 GND SB2 - Ground SB2 - Ground A9 GND SB3 - Ground SB3 - Ground A10 SB4_CONB SB4 - Reset SB4 - SDataOut A11 SB5_CONB SB5 - Backplane Address SB5 - SDataIn B11 CONTROLLER_TYPEB_BUF SB6 – Controller Type SB6 – Controller Type A8 BACKPLANE_TYPEB SB7 –
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 119 J17: Pin Number Signal Description 22-55-2081 Pin Number 1 +3.3V CONNECTOR J18-PORT0 Anode 2 2 ACT8_15_LED_L (0) CONNECTOR J18-PORT0 Cathode 1 3 +3.3V CONNECTOR J18-PORT1 Anode 4 4 ACT8_15_LED_L (1) CONNECTOR J18-PORT1 Cathode 3 5 +3.3V CONNECTOR J18-PORT2 Anode 6 6 ACT8_15_LED_L (2) CONNECTOR J18-PORT2 Cathode 5 7 +3.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 120 J7: The following pins are tied to Sideband Signals of SFF-8087 connector J3 (Ports 0-3) Pin Number Signal Description 1 SDA_A I2C Data – Connector J3 Ports 0-3 2 GND Ground 3 SCL_A I2C Clock – Connector J3 Ports 0-3 ● Adaptec 31205 I2C Board Connector: Molex 22-43-6030 or equivalent ● I2C Mating Cable Connector: Molex 22-43-3030 or equivalent J8: The following pins are tied to Sideband Signals of SFF-8087 connect
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 121 SFF-8087 Connector J5: Pin Number Signal I2C Description SGPIO Description B8 SB0_CONB SB0 - 2W_SCL SB0 - SClock B9 SB1_CONB SB1- 2W_SDA SB1- SLoad B10 GND SB2 - Ground SB2 - Ground A9 GND SB3 - Ground SB3 - Ground A10 SB4_CONB SB4 - Reset SB4 - SDataOut A11 SB5_CONB SB5 - Backplane Address SB5 - SDataIn B11 CONTROLLER_TYPEB_BUF SB6 – Controller Type SB6 – Controller Type A8 BACKPLANE_TYPEB SB7 –
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● Board Pin Number Signal Description 22-55-2161 Pin Number 10 ACT0_7_LED_L (4) CONNECTOR J5-PORT0 Cathode 9 11 +3.3V CONNECTOR J5-PORT1 Anode 12 12 ACT0_7_LED_L (5) CONNECTOR J5-PORT1 Cathode 11 13 +3.3V CONNECTOR J5-PORT2 Anode 14 14 ACT0_7_LED_L (6) CONNECTOR J5-PORT2 Cathode 13 15 +3.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 123 ● Adaptec 31605 Aggregate Activity LED Board Connector: Molex 22-28-8022 2.54mm 1x2 RA Header or equivalent ● LED Mating Cable Connector: Molex 50-57-9002 or equivalent J12: Pin Number Signal Description 2 AGGREGATE4_7_L Aggregate Cathode – Connector J5 Ports 0-3 1 +3.3V Aggregate Anode ● Adaptec 31605 Aggregate Activity LED Board Connector: Molex 22-28-8022 2.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 124 The following pins are tied to Sideband Signals of SFF-8087 connector J5 (Ports 0-3) Pin Number Signal Description 1 SDA_B I2C Data – Connector J5 Ports 0-3 2 GND Ground 3 SCL_B I2C Clock – Connector J5 Ports 0-3 ● Adaptec 31605 I2C Board Connector: Molex 22-43-6030 or equivalent ● I2C Mating Cable Connector: Molex 22-43-3030 or equivalent J19: The following pins are tied to Sideband Signals of SFF-8087 connector
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 125 SFF-8087 Connector J5: Pin Number Signal I2C Description SGPIO Description B8 SB0_CONB SB0 - 2W_SCL SB0 - SClock B9 SB1_CONB SB1- 2W_SDA SB1- SLoad B10 GND SB2 - Ground SB2 - Ground A9 GND SB3 - Ground SB3 - Ground A10 SB4_CONB SB4 - Reset SB4 - SDataOut A11 SB5_CONB SB5 - Backplane Address SB5 - SDataIn B11 CONTROLLER_TYPEB_BUF SB6 – Controller Type SB6 – Controller Type A8 BACKPLANE_TYPEB SB7 –
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● 126 Adaptec 4800SAS LED and I2C Connector Specification 2183100JA-R ASR-4800SAS/JA RoHS KIT 2183100-R ASR-4800SAS RoHS KIT 2185600-R ASR-4800SAS/128MB RoHS SGL 2185700-R ASR-4800SAS/256MB RoHS SGL ● Adaptec 4800SAS Activity LED Board Connector: Molex 10-89-7102 2.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference Pin Number Signal Description 16 GND SB2 - Ground 17 GND SB3 - Ground 18 INTB_P18 SB4 - Reset 19 INTB_P19 SB5 - Backplane Address ● 127 Adaptec 4805SAS LED and I2C Connector Specification 2183300JA-R ASR-4805SAS/JA RoHS KIT 2183300-R ASR-4805SAS RoHS KIT 2185800-R ASR-4805SAS/128MB RoHS SGL 2185900-R ASR-4805SAS/256MB RoHS SGL ● Adaptec 4805SAS Activity LED Board Connector: Molex 10-89-7102 2.
Appendix F: Adaptec Serial Controller LED and I2C Connector Reference ● Pin Number Signal Description 18 INTA_P18 SB4 - Reset 19 INTA_P19 SB5 - Backplane Address Pin Number Signal Description 14 INTB_P14 SB0 - 2W_SCL 15 INTB_P15 SB1- 2W_SDA 16 GND SB2 - Ground 17 GND SB3 - Ground 18 INTB_P18 SB4 - Reset 19 INTB_P19 SB5 - Backplane Address SFF-8484 Connector J7: 128
Safety Information G To ensure your personal safety and the safety of your equipment: ● Keep your work area and the computer clean and clear of debris. ● Before opening the system cabinet, unplug the power cord. Electrostatic Discharge (ESD) ! Caution: ESD can damage electronic components when they are improperly handled, and can result in total or intermittent failures. Always follow ESD-prevention procedures when removing and replacing components.
Technical Specifications H In this appendix... Environmental Specifications.............................................................................................. 131 DC Power Requirements...................................................................................................... 131 Current Requirements..........................................................................................................
Appendix H: Technical Specifications ● 131 Environmental Specifications Note: With a Battery Backup Unit (BBU), the ambient temperature should not exceed 40 °C Ambient temperature without forced airflow 0 °C to 40 ° C Ambient temperature with forced airflow 0 °C to 55 ° C Relative humidity 10% to 90%, noncondensing Altitude Up to 3,000 meters Note: Forced airflow is recommended.
Index A ACU arrays 44 creating arrays 44, 85 creating bootable arrays 86 initializing disk drives 86 managing arrays 86 rescanning disk drives 86 secure erasing disk drives 87 stopping a secure erase 87 ACU for DOS 93 to 103 array definition block keywords 97 creating a floppy disk 94 menus 94 playback mode 95 record mode 96 sample scripts 102 script file syntax 96 scripts 95 switches 95 Adaptec customer support 3 Adaptec Flash Utility.
Index creating 43, 86 C cables 33 cards.
Index driver and UnixWare 53 driver and VMWare 53 driver and Windows 50 existing operating system 36 external devices 42 installation options 35 SAS backplane 40 SAS direct-attach 39 with operating system 35 E electrostatic discharge 129 Enable Disconnection setting 90 end devices 69 End property 98 enhanced features 17 event log 92 expander connections 73 expander devices 69 external devices 42 F failed disk drives 65 multiple arrays 66 multiple disk drives 67 RAID 0 arrays 66 without hot spare 66 featu
Index P Packetized setting 90 parity 31 Phy Rate setting 89 phys 70 Physical Drives Display During POST setting 88 playback mode 95 Q QAS setting 90 R RAID 16, 17 non-redundant arrays 76 RAID 0 76 RAID 1 77 RAID 10 78 RAID 1E 16, 77 RAID 5 79 RAID 50 81 RAID 5EE 16, 80 RAID 6 16, 82 RAID 60 17, 82 RAID controllers. See controllers RAID levels 31 record mode 96 recovering from disk drive failure 65 Red Hat driver installation 57 OS installation 50 Redundant Array of Independent Disks.
Index disk drives 32 Enable Disconnection setting 90 Initiate Wide Negotiation setting 90 Maximum Transfer Rate setting 90 modifying with -Select utilities 90 Packetized setting 90 QAS setting 90 SCSI Parity Checking setting 90 SCSI Parity Checking setting 90 SCSISelect 87 secure erasing disk drives 87 stopping a secure erase 87 -Select utilities 87 applying changes 87 exiting 87 modifying controller settings 88 opening 87 Serial ATA. See SATA Serial Attached SCSI.
Adaptec, Inc. 691 South Milpitas Boulevard Milpitas, CA 95035 USA ©2005 Adaptec, Inc. All rights reserved. Adaptec and the Adaptec logo are trademarks of Adaptec, Inc. which may be registered in some jurisdictions.