adoptee ASW-1440 Version 3 ASPI Manager with Disk Module for Novell NetWare 286/386 Installation Guide
Preface COPYRIGHT Copyright 1991 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Adaptec, Inc. 691 South Milpitas Blvd., Milpitas, CA 95035 TRADEMARKS Novell, NetWare, and "NetWare Ready" are trademarks of Novell, Inc.
Table of Contents 1.0 INTRODUCTION.................................................................................1-1 1.1 WHAT IS ASPI? .........................................................................1-3 1.2 WHAT YOU NEED TO GET STARTED ......................................... 1-3 1.3 OTHER DOCUMENTATION THAT MAY HELP ............................ 1-4 2.0 NETWARE 386 V3.1 INSTALLATION..................................................2-1 2.1 COMMAND LINE OPTIONS ...................................
Table of Contents 4.0 NETWARE 286 INSTALLATION ..........................................................4-1 4.1 STEP-BY-STEP INSTALLATION ................................................. .4-2 4.2 MULTIPLE DISK DRIVES WITHNETWARE 286 V2.15 ................ .4-9 4.2.1 Mirroring..................................................................... .4-9 4.2.2 Duplexing.................................................................... .4-14 4.2.3 Multiple Channels per Host Adapter (Multitasking) ...........
Section One Introduction This document provides installation information if you are installing Adaptec's AHA 1540A, AHA-1542A, AHA-1540B, AHA-1542B, AHA-1640, AHA-1740, or AHA-1744 SCSI host adapters into a Novell NetWare file server. The versions of NetWare supported are NetWare 286 2.15 (SF[ or Advanced), NetWare 386 v3.0, and NetWare 386 v3.1.
Section One Introduction Files ih: \NET286.215\VER3_2 File Purpose README.TXT This is an ASCII text file describing the NetWare drivers for NetWare 286 v2.1S. ASWNOVL.OBJ ASWNOVL.DSK These are v3.2 of Adaprec's NetWare 286 v2.1S driver for the AHA-1S40/1S42, AHA-1640, and the standard mode of the AHA-1740/1744. These drivers allow the AHA-1640 to be configured to Arbitration Level 4. One of the configuration options has changed as well. Files in: \NET286.30 File Purpose README.
Section One 1.1 Introduction WHAT IS ASPI? ASPI stands for Advanced SCSI Programming Interface. It is a programming interface which allows for multiple drivers to share the same SCSI host adapter. This allows for mUltiple types of SCSI devices (Le., tape, disk, CD-ROM, etc.) to be placed on one SCSI host adapter. This keeps cost down while freeing up your internal slots. An ASPI manager is included in both the NetWare 386 v3.0 and NetWare 386 v3.1 drivers.
Section One 1.
Section Two NetWare 386 v3.1 Installation We recommend that you make backup copies of all Novell and Adaptec supplied diskettes using "DISKCOPY" and use those backup copies as your working diskettes. Use the NetWare 386 v3.1 file SERVER.EXE to start the installation process. You will be prompted for a file server name and an IPX internal network number. Consult the NetWare 386 user's manual for this information. Installing a disk driver into NetWare 386 requires use of the LOAD console command.
Section Two NetWare 386 v3.1 Installation Note: If installing more than one host adapter. each host adapter should have its own SCSI bus. For example. no two AHA-1540s should be connected to the same SCSI cable. The NetWare 386 prompt (":") will now be displayed. Use the LOAD command to install the driver. The correct syntax to load the AHA-I 540/1542 driver is: I :load [path] aha1540 [options] Note that this driver is used for the AHA-1740/1744 running in standard mode.
Section Two NetWare 386 v3.1 Installation For an AHA-I640, the screen will look similar to: :load a:\net386.31\aha1640 Auto-loading Module ASPITRAN.DSK AHA-154x/1640 ASPI Manager & SCSI Disk Module For NetWare 386 v3.1 Version 2.0 Copyright 1990 Adaptec, Inc. Supported Slot values are 1, 2 Slot: 1 To automate this procedure, the user can type: "load a:\net386.31'ahaI540 slot=x" where 'x' is the host adapter's slot location.
Section Two 2.1 NetWare 386 v3.1 Installation COMMAND LINE OPTIONS There are several command line options that can be specified when the driver is loaded. These are described below. Option port= speed= Possible Values Host Adapter 330 334 234 230 134 130 AHA 1540/1542 This option selects the host adapter's port address. This should correspond to the jumpered port address of the AHA 1540/1542. If none is given, the user will be prompted for one. Port 330H is the default value.
Section Two NetWare 386 v3.1 Installation Possible Values Host Adapter 1-8 AHA-I640 This option selects the host adapter's slot location. If none is given, the user will be prompted for one. verbose:::: y AHA 1540/1542 AHA-I640 AHA 1740/1744 With this option, the driver will display host adapter configuration information during load time. removable:: off AHA 1540/1542 AHA-I640 AHA 1740/1744 This option disables support for removable media. By default, removable media is supported.
Section Two NetWare 386 v3.1 Installation Here is an example of the driver being loaded with command line options used. :load ahalS40 port=330 verbose=y speed=O Loading module AHA1540.DSK Auto-loading Module ASPITRAN.DSK AHA-154x/1640 ASPI Manager & SCSI Disk Module For NetWare 386 v3.1 Version 2.0 Copyright 1990 Adaptee, Inc.
Section Two 2.2 NetWare 386 v3.1 Installation MULTIPLE DISK DRIVES WITH NETWARE 386 V3.1 The NetWare 386 v3.1 drivers support the installation of multiple SCSI hard disk drives in the file server. This might be desired for several reasons: - to support disk mirroring (fault tolerance) to support disk duplexing (fault tolerance) to increase total storage capacity of the system to install multiple drives per NetWare volume. Disk mirroring and disk duple xing are described below. 2.2.
Section Two NetWare 386 v3.1 Installation - The SCSI devices on the ends of the SCSI cable must have the terminators installed. All other SCSI devices on that SCSI cable should have the terminators removed. The AHA-1540/1542/1640/1740/l744 is considered a SCSI device and has on-board terminators that should be removed only if both the internal and external SCSI connectors are used at the same time. The NetWare procedure for installing a mirrored pair of disk drives is similar to the standard installation.
Section Two NetWare 386 v3.1 Installation Select "Disk Options". The screen should look similar to: Select "Partition Tables".
Section Two NetWare 386 v3.1 Installation The screen should display the installed disk drives. Consult the NetWare 386 Installation manual on how to create partitions on each drive. After each drive has a NetWare partition on it, return to the "Available Disk Options" menu and select "Mirroring". The screen should look similar to: Select "Not Mirrored: Logical Partition #1", which is in this case the Quantum Pro lOSS.
Section Two NetWare 386 v3.1 Installation Press , and the screen will look similar to: Press , then . The screen will look similar to: The drives are now mirrored. Press several times to exit the INSTALL program.
Section Two 2.2.2 NetWare 386 v3.1 Installation Duplexing Disk duplexing is when two host adapters are installed in a single file server, each with its own disk mirrored together. These disk drives contain the same data. This ensures that if either one disk or one host adapter fails, the server will continue to operate.
Section Two NetWare 386 v3.1 Installation - If both of the host adapters are AHA-l542s (e.g., both have floppy controllers), one of the floppy controllers should be disabled by removing the floppy enable jumper. - The Interrupt Channels (referred to as Interrupt Level with the AHA-I640) must be different on the two host adapters. The Interrupt channel can be changed by changing jumpers on the AHA-l 540/1542.
Section Two NetWare 386 v3.1 Installation The procedure for duplexing requires that the NetWare 386 driver be loaded twice. The screen will look similar to: :load AHAl540 port=330 Loading module AHA1540.DSK Auto-loading Module ASPITRAN.DSK AHA-154x/1640 ASPI Manager & SCSI Disk Driver For NetWare 386 v3.1 Version 2.0 Copyright 1990 Adaptec, Inc. :load AHA1540 port=334 Loading module AHA1540.DSK AHA-154x/1640 ASPI Manager & .sCSI Disk Driver For NetWare 386 v3.1 Version 2.
Section Two 2.3.1 NetWare 386 v3.1 Installation Booting From SCSI If you have an AHA-1540/1542 and you wish to boot from SCSI, you should have your BIOS enabled on the host adapter at port 330h: If you have an AHA-I640, you should have your BIOS enabled on a single host adapter at port 330h, 230h, or 130h. If you have other host adapters installed, you should disable their BIOS. If you have an AHA 1740/1744 in enhanced mode, use the configuration diskette to configure the boards.
Section Two NetWare 386 v3.1 Installation The STARTUP.NCF should look similar to: iload aspitran load ahal540 port~330 IMPORT ANT: In order for STARTUP.NCF to properly execute, the module ASPITRAN.DSK must be loaded before AHA1540.DSK, AHAl640.DSK, or AHA1740.DSK. 2.3.3 Formatting Media NetWare 386's "INSTALL.NLM" program lets you optionally format a disk drive. When using SCSI, it allows you to low-level format several SCSI drives simultaneously.
Section Two 2.3.4 NetWare 386 v3.1· Installation Removable Media AHAI540.DSK v2.0, AHAl640.DSK v2.0, and AHA1740.DSK v1.0, have full support for removable media disk drives including magneto-optical drives. Removable media is treated as a standard SCSI hard disk, with some exceptions. The driver will only recognize and register media with 512 bytes/sector. NetWare 386 v3.1 allows you to mount/dismount the media, and to lock/unlock the media These options are supported in the NetWare MONITOR.NLM program.
Section Two 2.3.5 NetWare 386 v3.1 Installation 16-Megabyte Limitation Due to a hardware limitation of the AT bus, the AHA-1540/1542/1640 can only access up to 16 MBytes of memory in your server. If you have more than 16 MBytes, you should set this flag at the NetWare console in your STARTUP.NCF: :set Auto Register Memory Above 16 Megabytes = OFF If you have an EISA machine with more than 16 MBytes, you should use the Adaptec AHA-1740/1744, running in enhanced mode, to access up to 4 GigaBytes.
Section Two 2.4 NetWare 386 v3.1 Installation ERROR MESSAGES UNDER NETWARE 386 V3.1 Any error which occurs, during initialization, will cause the driver NOT to be loaded. If an error does occur, the driver will first "beep" the computer and then display a numbered error message in the following format: I ERR xxx:message The "xxx" indicates the error code.
Section Two 003 NetWare 386 v3.1 Installation Invalid command line option entered -> option An invalid option was entered on the command line. The 'option' field displays the invalid option which was entered. 004 Invalid command line, please enter correctly The driver was unable to understand the command line options which were entered by the user. Please be sure you enter them correctly. 005 Unable to load driver - not enough memory? The driver was unable to load itself.
Section Two 1103 NetWare 386 v3.1 Installation Invalid 'bus_on' setting, use 2-15 You have entered an invalid 'bus_on' setting on the command line. You can only enter decimal numbers 2-15 (i.e., "bus_on = 9"). This option is only valid for the AHA-1540/1542. 104 Invalid 'bus off' setting, use 1-64 You have entered an invalid 'bus_off setting on the command line. You can only enter decimal numbers 1-64 (i.e., "bus_off = 10"). This option is only valid for the AHA-1540/1542.
Section Two 1111 NetWare 386 v3.1 Installation No host adapter found The driver failed in its attempt to find a host adapter in your system. Please be sure the host adapter is properly inserted. 112 Host adapter not found at given port location The driver failed in its attempt to find a host adapter at the user-entered location. Please be sure you have entered the correct port address.
Section Two 117 NetWare 386 v3.1 Installation Unable to initialize host adapter's mailbox location The driver failed in its attempt to initialize the host adapter's mailbox base address. Make sure there are no hardware conflicts within your PC and that the host adapter is securely inserted. 118 Invalid 'removable' setting, use 'off' You can only enter 'off for this option (i.e., "removable = off'). 119 Invalid 'fixed disk' setting, use 'off' You can only enter 'off for this option (i.e.
Section Two 204 NetWare 386 v3.1 Installation Invalid 'verbose' setting, use 'y' You can only enter 'y' for this option (i.e., "verbose = y"). 205 Invalid 'removable' setting, use 'off' You can only enter 'off for this option (i.e., "removable = off'). 206 Invalid 'fixed disk' setting, use 'off' You can only enter 'off for this option (i.e., fixed_disk = off).
Section Three NetWare 386 v3.0 Installation We recommend that you make backup copies of all Novell and Adaptec supplied diskettes using "DISKCOPY" and use those backup copies as your working diskettes. Use the NetWare 386 v3.0 file SERVER.EXE to start the installation process. You will be prompted for a file server name and an IPX internal network number. Consult the NetWare 386 Installation manual for this information. The NetWare 386 prompt (":") will now be displayed.
Section Three NetWare 386 v3.0 Installation For an AHA-1640, the screen will look similar to: :load a:\net386.30\asw1440 Loading module asw1440.DSK ASW-1440: AHA-154x/1640 ASPI Manager & SCSI Disk Driver For NetWare 386 Version 1.0 Copyright 1990 Adaptec, Inc. Supported Slot values are 1, 2, 3, 4, 5, 6, 7, 8 Slot: ~ To automate this procedure, the user can type: "load a:\net386.31\ahal640 slot=x" where 'x' is the host adapter's slot location.
Section Three 3.1 NetWare 386 v3.0 Installation COMMAND LINE OPTIONS There are several command line options that can be specified when the driver is loaded. These are described below. Option Possible Values Host Adapter Description port= 330 334 234 230 134 130 AHA This option selects the host adapter's port 1540/1542 address. This should correspond to the jumpered port address of the AHA-1540/1542. If none is given, the user will be prompted for one.
Section Three NetWare 386 v3.0 Installation Option Possible Values removable:: off AHA This option disables support for removable 1540/1542 media. By default, removable media is AHA-1640 supported. A user may want to disable "removable" disk support in order to load their own ASPI Removable Disk Module.* fixed_disk= off This option disables support for fixed disk AHA 1540/1542 drives. By default, fixed disk drives are AHA-1640 supported.
Section Three 3.2 NetWare 386 v3.0 Installation MIRRORING AND DUPLEXING Mirroring and duplexing SCSI drives is similar under NetWare 386 v3.0 as it is under NetWare 386 v3.1. Please consult the section on mirroring and duplexing found in the NetWare 386 v3.1 installation section for more information. 3.3 SPECIAL CONSIDERATIONS This section discusses such various topics as how to boot a NetWare 386 server from SCSI, and the 16 MByte limitation. 3.3.
Section Three NetWare 386 v3.0 Installation A sample AUTOEXEC.NCF will look similar to: file server name MYFILESERVER ipx internal net 2 mount all Replace MYFILESERVER with the desired file server name. Consult the NetWare installation guide for an appropriate ipx internal net number. The STARTUP.NCF should look similar to: I load asw1440 port=330 3.3.3 16-Megabyte Limitation Due to a hardware limitation of the AT bus, the AHA-1540/1542/1640 can only access up to 16 MBytes of memory in your server.
Section Three 3.4 NetWare 386 v3.0 Installation ERROR MESSAGES Any error which occurs, during initialization, will cause the driver NOT to be loaded. If an error does occur, the driver w;ll first "beep" the computer and then display a numbered error message in the following format I ERR xxx:message The "xxx" indicates the error code. The error codes are broken up into three sections.
Section Three 003 NetWare 386 v3.0 Installation Invalid command line option entered -:> option An invalid option was entered on the command line. The "option" field displays the invalid option which was entered. 004 Invalid command line, please enter 'correctly The driver was unable to understand the command line options which were entered by the user. Please be sure you enter them correctly. 3.4.2 AHA-lS40/1S42/1640 Specific Error Codes Code 100 Message Invalid 'port' setting (enter in hex, ie.
Section Three 104 NetWare 386 v3.0 Installation Invalid 'bus off' setting, use 1-64 You have entered an invalid 'bus_off setting on the command line. You can only enter decimal number 1-64 (i.e .• "bus_off = 10"). This option is only valid for the AHA-1540/1542. 105 Invalid 'verbose' setting, use 'y' You can only enter 'y' for this option (i.e., "verbose = y"). 106 'speed' option only valid for a 154x host adapter You have attempted to set the Bus Master DMA transfer rate on the AHA 1640.
Section Three 112 NetWare 386 v3.0 Installation Host adapter not found at-given port location The driver failed in its attempt to find a host adapter at the user-entered location. Please be sure you have entered the correct port address. 113 Unable to read configuration from 154x host adapter The driver failed in its attempt to get the bost adapter's configuration settings (Adapter Inquiry command). This error will only occur with the AHA-1540/1542.
Section Three 118 NetWare 386 v3.0 Installation. Invalid 'removable' setting, use 'off' You can only enter 'off for this option (i.e., "removable = off'). 119 Invalid 'fixed_disk' setting, use 'off' You can only enter 'off for this option (i.e., "fixed_disk ASW-1440 3-11 = off").
Section Four NetWare 286 v2.15 Installation We recommend that you make backup copies of all Novell and Adaptec supplied diskettes using "DISKCOPY" and use those backup copies as your working diskettes. NETGEN.EXE is the NetWare program used to create a file server. Described below are several methods of installing NetWare. Complete installation instructions can be obtained from the Novell NetWare user's manual. The drivers for NetWare 286 only support the AHA-1740/1744 when running in standard mode.
Section Four 4.1 NetWare 286 v2.15 Installation STEP-BY-STEP INSTALLATION Described below is a recommended step-by-step installation using the Hard Disk method (the Network drive method is similar). Other methods of installation are available and are described in the NetWare installation manual. Type NETGEN -N at the DOS prompt. The display will look similar to: Move the cursor to "Custom Configuration" and select it by hitting enter.
Section Four NetWare 286 v2.15 Installation The following screen will appear: Select "Hard Disk". You will be prompted for the logical drive letter that contains"the NetWare subdirectories previously created. The following screen will appear: Select the "Select Network Configuration" option.
Section Four NetWare 286 v2.15 Installation The following are the Available Options available during Network Configuration: I Network Configuration V4.02 Select Resource Sets Select LAN Drivers Select Disk Drivers Select -other- Drivers Configure Drivers f Resources Edit Resource List Edit Resource Sets In general, at least the following options should be selected: Options Purpose Set Operating System Options This option is used to set the mode of operation of NetWare 286.
NetWare 286 v2.1S Installation Section Four Select the "Select Disk Drivers" option. The following will describe the Disk Driver installation. The display will look similar to: I Network Configuration Se Se Se Se Se V4.02 0 1 2 3 4 .~~::-;:::::===:::EffiIT§~~~~ Co Edit Resource List Edit Resource Sets There are five channels available for installing disk drivers.
Section Four NetWare 286 v2.15 Installation Choose the "Load and Select Item" Option. The ASW-1440 v3.0 drivers will be read from all DSK_DRV_.XXX subdirectories, including the DSK_DRV_.209 subdirectory, which you created at the beginning of the installation. The following screen will appear: I Network Configuration V4.02 Press ESCAPE to continue. You will then be prompted for a Channel number (see following diagram). Valid channel numbers are between 0 and 4.
NetWare 286 v2.1S Installation Section Four After selecting all of the desired drivers, select "Configure Drivers / Resources" from the Available Options menu. The "Configure Drivers /Resources" menu will appear and look similar to: I Network Configuration V4.02 (ENTER) key. Press ESCAPE to save selections and continue Only "Choose Disk Driver Configuration" is described here. Consult the NetWare installation manual for information on "Choose LAN Configuration" and "Enter Server Information" .
Section Four NetWare 286 v2.1S Installation Select "Choose Disk Driver Configuration". All unconfigured disk driveri; will be displayed. Select the unconfigured Adaptec driver. The following list of Available Disk Configurations will appear: I Network Confi\luration V4.
Section Four 4.2 NetWare 286 v2.1S Installation MULTIPLE DISK DRIVES WITH NETWARE 286 V2.1S The NetWare 286 drivers in ASW-1440 v3.0 supports the installation of multiple SCSI hard disk drives in the file server.
Section Four NetWare 286 v2.1S Installation - The drives must be connected on the same SCSI cable on the same AHA 1540/1542/1640/1740/1744. - The SCSI ID of the drives must be different (Note: If booting is desired from one of the SCSI drives. its SCSIID must be jumpered to 0 and the port address ofthe host adapter should be set to 330H). - The SCSI devices on the ends of the SCSI cable must have the terminators installed. All other SCSI devices on that SCSI cable should have the terminators removed.
NetWare 286 v2.15 Installation Section Four Menu Meaning Drive Name This is the Inquiry data from the SCSI disk drive. Channel This is the NetWare channel that the drive was assigned to. Controller This is the SCSI I.D. of the disk drive. Drive This is the logical unit number (LUN) of the Controller. Status This provides infonnation when drives are mirrored or duplexed. The drives listed should match the drives that are installed on the AHA-1540/1542/1640.
Section Four NetWare 286 v2.1S Installation The following "Installation Options" will appear: Choose "Select Default Installation Options". The screen will display mirroring options. By default, the drives will not be mirrored and the screen will look similar to: SFT Netware + TTS Install V4.
NetWare 286 v2.1S Installation Section Four To mirror them select "Establish Mirror Pair". The screen will then look like: SFT Netware + TTS Install Monday Auqust 20, 1990 V4.00 To unmirror the drives again, select "Un-mirror Existing Mirror Pair". When mirroring is enabled or disabled, as desired, select "Done, Continue Installation" to continue. Follow NetWare installation manual for naming the file server, installing the files, and other instructions.
Section Four 4.2.2 NetWare 286 v2.15 Installation Duplexing Disk duplexing is when two host adapters are installed in a single file server, each with its own disk. These disk drives contain the same data. This ensures that if either one disk or one host adapt~r fails, the system will continue. 386/.:186 • Disks contain same data • Host adapters at different port address/IRQ/DMA • Driver must be loaded twice Mirroring and duplexing are both referred to as "mirroring" in the NetWare operating system.
Section Four NetWare 286 v2.1S Installation - If both of the host adapters are AHA-1542s (e.g., both have floppy controllers), one of the floppy controllers should be disabled by removing the floppy enable jumper. - The Interrupt Channels (referred to as Interrupt Level with the AHA-I640) must be different on the two host adapters. The Interrupt channel can be changed by changing jumpers on the AHA-1540/1542.
Section Four NetWare 286 v2.1S Installation The SCSI devices on the ends of the SCSI cable must have the terminators installed. All other SCSI devices on that SCSI cable should have the terminators removed. The AHA-1540/1542/1640/1740/1744 is considered a SCSI device and has on-board terminators that can be removed if both the internal and external SCSI connectors are used at the same time. The procedure for duplexing requires that the NetWare 286 driver be loaded twice.
Section Four NetWare 286 v2.15 Installation After both drivers are successfully selected, the screen should look similar to: I Net work Cont igura t ion V4 .02 Configure the NetWare 286 driver with the option that corresponds to the settings of the AHA-1540/1542/1640/1740/1744. When the NetWare 286 driver at channell is configured from the "Configure Drivers / Resources" menu only a subset of the total number of configurations will be displayed.
Section Four NetWare 286 v2.15 Installation The screen will look similar to: Press Fl For Help If necessary use the arrow keys to view all drives. Then press the ESCAPE key to continue. The drives listed should match the drives that are installed on the AHA 1540/1542/1640/1740/1744. Verify that the drives listed match the actual drives installed and press .
NetWare 286 v2.15 Installation Section Four Select "Drive List is Correct" to continue. The following "Installation Options" will appear: + TTS Install V4.00 Choose" Select Default Installation Options". The screen will display mirroring options. By default the drives will not be duplexed (mirrored), and the screen will look similar to: Monday August 20, 1990 5:44 pm the SELECT (enter) key.
Section Four NetWare 286 v2.15 Installation To duplex the drives select "Establish Mirror Pair" .
Section Four NetWare 286 v2.15 Installation To unduplex the drives again, select "Un-mirror Existing Mirror Pair". When duplexing is enabled or disabled, as desired, select "Done, Continue Installation" to continue. Follow NetWare installation manual for naming the file server, installing the files, and other instructions. 4.2.
Section Four - NetWare 286 v2.1S Installation The SCSI devices on the ends of the SCSI cable must have the terminators installed. All other SCSI devices on that SCSI cable should have the terminators removed. The AHA-1540/1542/1640/1740/1744 is considered a SCSI device and has on-board terminators that can be removed if both the internal and external SCSI connectors are used. The NetWare procedure for assigning multiple channels per host adapter is similar to the standard installation.
NetWare 286 v2.15 Installation Section Four Configure the driver at channel 0 to the correct I/O port, DMA channel, and Interrupt channel. When configuring the driver at channell, only a subset of the total number of configuration options will appear. Use the down arrow key to scroll to options 19 through 31. The screen will look something like: Configuration 19: 20: 21: 22: 23: ASW-1440 For For For For For I/O SCSI SCSI SCSI SCSI SCSI port V4.
Section Four NetWare 286 v2.15 Installation Select the option that corresponds to the channel that was used to configure the correct DMA channel and Interrupt channel. In this case, option 19, "For SCSI disk(s) attached to CH 0 AHA-1540/1542/1640/1740/1744 Only" would be chosen, since channel 0 was used to configure the DMA channel and Interrupt channel for the AHA 1540/1542/1640/1740/1744.
Section Four NetWare 286 v2.15 Installation 4.3 COMMONLY ASKED QUESTIONS ON NETWARE 286 Q. Do I need ASW-I440 v2.0 if I'm using my AHA-1540/1542/1640 in a Novell NetWare workstation? A. No, the driver is only required if the AHA-l 540/1542/1640 is to used in afile server. It is not required when using the AHA-l 540/1 542/1640 in a workstation. Q. Does ASW-1440 also work with Adaptec's single user AHA-I 520/1522 host adapter? A. No.
Section Four NetWare 286 v2.1S Installation Q. What is the "Write Verify" configuration option? A. Each configuration option 0./0 base address /REQ / DMA) can be configured to "Write" or "Write Verify". For example, for a host adapter at port 330H, IRQ 11, and DMA channel 5, option 1 should be used for "Write" only or option 25 for "Write Verify". Standard "Write" will use the SCSI write command when writing data to the hard disk.
Section Four AHA154x/1640 AHAl54x/l640 AHA154x/1640 AHAl54x/1640 AHA154x/1640 AHA154x/1640 AHAl54x/1640 AHA154x/1640 AHA154x/1640 AHA154x/1640 AHA154x/1640 NetWare 286 v2.15 Installation Host Adapter is not idle while trying to reset interrupt. Can't send a byte due to Command/Data port still FULL. Can't get a byte due to Data port not FULL. configuration data contains no DMA channel. configuration data contains no interrupt channel. INQUIRY command Completed with Error or Time Out.
Section Four 4.5 NefWare 286 v2.1S Installation HOST ADAPTER OPTIONS The following configurations are supported options of the AHA-1540/1542. OPTION # Write Verify Option # PORT IRQ DMA 1 25 330H 11 5 2 26 330H 12 .
Section Four NetWare 286 v2.15 Installation Whichever hardware configuration option you do select you must make sure that this is reflected on the actual AHA-lS40/1542 host adapter via the jumper blocks. The following configurations are supported options of the AHA -1640.
adoptee STOCK NO.: 510149-00 Rev.B 1H 2/91 Prin1edlnSingapore 691 south milpitas blvd .• milpitas. ca 95035.