Technical data

System Management Release Notes
5.7 Lock Manager
Because of this change to nonpaged pool, Compaq recommends the following
steps:
Use AUTOGEN with feedback information to tune the size of nonpaged pool.
Inspect MODPARAMS.DAT to check for any NPAGEDYN or NPAGEVIR
settings previously made to increase the size of nonpaged pool due to the lock
managers usage.
You may find that these parameters can be either trimmed back or removed
due to changes to the lock manager.
The SHOW MEMORY documentation in the OpenVMS DCL Dictionary: N–Z
describes the memory associated with the lock manager.
5.8 OPCOM
This section contains release notes pertaining to the Operator Communication
Manager (OPCOM).
5.8.1 OPCOM Messages Changed (Alpha Only)
V7.2
In OpenVMS Alpha Version 7.2 and later, OPCOM messages from the job
controller and the queue manager now display SYSTEM as the user process. For
example:
%%%%%%%%%%% OPCOM 16-NOV-2000 15:07:49.33 %%%%%%%%%%%
Message from user SYSTEM on NODEX
%JBC-E-FAILCREPRC, job controller could not create a process
%%%%%%%%%%% OPCOM 16-NOV-2000 15:07:49.34 %%%%%%%%%%%
(from node BENN at 16-NOV-2000 15:07:49.34)
Message from user SYSTEM on NODEX
-QMAN-I-QUEAUTOOFF, queue NODEX$BATCH is now autostart inactive
The examples in the OpenVMS System Managers Manual do not currently reflect
this change.
5.8.2 Handling of Invalid Operator Classes
V7.3
Previously, if the OPC$OPA0_CLASSES or OPC$LOGFILE_CLASSES logicals
contained an invalid class, it would cause OPCOM to signal the error and run
down the process.
This problem has been corrected in OpenVMS Version 7.3.
The following two messages have been added to OPCOM:
%%%%%%%%%%% OPCOM 18-MAY-2000 13:28:33.12 %%%%%%%%%%%
"BADCLASS" is not a valid class name in OPC$LOGFILE_CLASSES
%%%%%%%%%%% OPCOM 18-MAY-2000 13:28:33.12 %%%%%%%%%%%
"BADCLASS" is not a valid class name in OPC$OPA0_CLASSES
If an invalid class name is specified in either of the logicals, the appropriate error
message is displayed. These messages are displayed on the console at system
startup and logged to the OPERATOR.LOG.
The list of all operator classes is:
CARDS
CENTRAL
System Management Release Notes 5–11