Installing and Configuring Enhanced OS-9
NE2000
ZF NetDisplay
ACCTON - EN166X MPX 2 Ethernet
D-LINK DE-220PCT - 10Mbps Combo 16-Bit Ethernet ISA Adapter
Compex - ReadyLink 2000 - PCI 32-bit
System State Debugging - Supported
Default Settings
PORTADDR 0x340 /* IO port for ISA */
IRQVECTOR 0x49 /* IRQ vector */
CONNTYPE INF_EXT /* Auto */
Board Setup Issues
ZF NetDisplay
use <CDROM>:\Drivers\Ethernet\Realtek\RSET8019.EXE"
to determine the IO address and IRQ required.
IO=0x340 VECTOR=0x49 is typical. Settings are system dependent.
ACCTON - EN166X MPX 2 Ethernet
use "1step" program located on the setup disk to set card to
jumpered "ne2000" mode.
IO=0x300 VECTOR=0x43 is typical. Settings are system dependent.
D-LINK DE-220PCT - 10Mbps Combo 16-Bit Ethernet ISA Adapter
Use "setup" program located on the setup disk "A:\SETUP\setup.exe"
to setup the card. Disable PNP and setup Interrupt and I/O base
address.
Compex - ReadyLink 2000 - PCI 32-bit
Just plug and go. Multiple cards may be used by using the
PCI Specific Settings listed below.
PCI Specific Settings Information