DocSTAR Level 2 Service Training Workbook Page 89
Section 3: RAID Lab
? This section will provide hands-on experience in installing and troubleshooting RAID
hardware and Two-Tier Storage software
Activity: Install the RAID hardware. For internal RAID create the Mirror and make
the RAID bootable. For the external RAID install the additional SCSI card and
attach the RAID Tower to it verifying that the Tower is terminated properly. Set the
Tower as the bootable drive. Next, boot the system with a Windows Boot Disk and
restore the system stamp to the new bootable RAID device. Add Two-Tier Storage
to the DocSTAR system through DocAdmin and the licensing screen. Now simulate
a failure of one of the RAID drives by turning the key to the off position on one
active drive. You may now monitor the indicated failure conditions on both the
Host PC software utility (Internal RAID) and the LCD Panel on the RAID Tower
(External RAID). Optionally: For the external RAID, you may also simulate one
power supply failure by switching one of the power supplies off.