Specifications
Page 84 DocSTAR Level 2 Service Training Workbook
Replacing a cooling fan:
1. While the External RAID is running, unscrew the 2
Fan Door Screws and swing fan door open.
2. Disconnect power connector for failed fan.
Note: The other fans are still turning. Please use
caution when replacing fan.
3. Unscrew the 4 fan screws and replace fan.
4. Connect new fan power connector.
5. Close fan door and screw Fan Door Screws back
into place.
Replacing a Hard Drive:
1. While the External RAID is running, identify
which drive has failed by the RED LED
indicator.
2. Unlock the failed drive and slide the drive
carrier out as shown at right.
3. Replace hard drive with new hard drive of
same size or larger set as Master, as shown
below. Note: It is highly recommended
that the same model hard drive be used in
all drive bays, for performance reasons.
4. Slide drive carrier w/new hard drive back in
and lock the drive.
5. Rebuild to the spare is automatic and should
already have taken place or be in progress.