User Manual

User Manual
S E R I E S
8
Power
When wiring an AC cable for use with this product in
a single-line system, use the wiring scheme described
below in Table 2 and illustrated with Fig. 1. All work
must be completed by a qualied technician.
Fig. 1
Hot or Live (L) Brown
Neutral (N) Blue
Protective Earth /
Ground (E or PE)
Green and Yellow
Table 2
powerCON True1 AC Cable Input Connector powerCON True1 AC Cable Output Connector
The CS Power Distribution Sysytem (PDS, 914-0002 - 110 V/914-0003 - 230 V) provides six individually
protected AC circuits of 208/230 V, 16 A power. When using the Adamson PDS, you can link a maximum of
three CS119 loudspeakers per circuit.
Brown
Blue
Green and Yellow
100 V 115V 120 V 208 V 230 V 240 V
RMS Long-Term 9.20 A 8.00 A 7.67 A 4.42 A 4.00 A 3.83 A
RMS Idle 1.04 A 0.90 A 0.86 A 0.50 A 0.45 A 0.43 A
Peak 55.20 A 48.00 A 46.00 A 26.54 A 24.00 A 23.00 A
Table 1 - Single cabinet current draw
Current draw for the CS119 is dynamic and fluctuates as operating levels change.