Installation Instructions

2 of 8
Specifications
PART NUMBERS & LOCATIONS
CIRCUIT BOARD PART NUMBER LOCATION
PS-EXIT 31-0725 Power Supply
Battery Backup System Kit BBK-EXIT Power Supply
PS-EXIT VOLTAGE MEASUREMENTS
OUT1/OUT2 when IN1/IN2 is OPEN: less than 1.6 VDC
OUT1/OUT2 when IN1/IN2 is CLOSED: 24 – 26 VDC
OUT1/OUT2 are rated at a maximum output current of 400 mA each.
LED INDICATORS
LED COLOR STATUS
Main Power RED ON when AC power is on
FIRE GREEN ON if no fire alarm condition
OUT1 GREEN ON during OUT1 unlock time interval
OUT2 GREEN ON during OUT2 unlock time interval
IN1 GREEN ON when contacts at IN1 are closed
IN2 GREEN ON when contacts at IN2 are closed
NOTE: The board must be replaced if OUT1 is on when IN1 is open or if OUT2 is on when IN2 is open.
PS-EXIT IS CLASSIFIED UNDER THE FOLLOWING UL294 PERFORMANCE LEVELS
Endurance, Level IV
Line Security, Level I
Destructive Attack, Level I
Standby Power, Level IV (with battery backup system BBK-EXIT)