Specification Sheet

Power supply with optional battery backup for all 3000
and 8000 exit devices with Silent Electrification Motorized
Latch Retraction (SE) option.
PS-SE Power Supply
Function
This power supply is required for the Silent Electrification Motorized Latch
Retraction (SE) option on Adams Rite exit devices. It operates at 24 VDC to power
up to two SE exit devices in sequential or independent modes. The PS-SE is also
equipped with a fire alarm disconnect interface circuitry.
Operating Modes
The PS-SE is designed to power up to two 3000 SE or 8000
SE exit devices in the following operating modes:
Sequential ModeA single input switch (Dry Contact)
operates two devices in sequential operation. Ideal for a
double-door setup.
Independent Mode – Each SE exit device is controlled
by its own input switch.
Specications
UL1012 + UL1310
INPUT POWER
115 VAC, 0.7A
PRIMARY FUSE
The PS-SE has two user-serviceable fuses:
F1: Transformer output: 2AMPS/250V 5x20MM
F2: Transformer input: 2AMPS/250V 5x20MM
OPEN HOLD TIMES
The PS-SE has two open hold timers. Hold open time
settings are adjustable from 2-60 seconds.
ENCLOSURE
Hinged, steel cabinet measures 10” x 10-3/8” x 4-1/8”.
Black, baked enamel finish, with knockouts for conduit
connections. Sized to accommodate two sealed, lead
acid batteries (7AH, not included).
OPTIONS
Battery Backup Kit (BBK-SE) available separately
to add battery backup capability to the PS-SE. The
enclosure is sized to accommodate two 12 volt – 7AH
sealed, lead acid batteries (not included).
Important Note
Adams Rite requires that for optimal performance all exit
devices with the SE option be paired with PS-SE power
supplies. Failure to do so may cause permanent damage to
the exit device and will void the Manufacturer’s warranty.