Product Manual
Table Of Contents
- 1.0 INTRODUCTION
- 2.0 TECHNICAL SPECIFICATIONS
- 3.0 UNPACKING THE SCALE
- 4.0 SETTING UP THE SCALE
- 5.0 KEYPAD AND DISPLAY
- Description
- Symbol
- 6.0 FUNCTIONS
- 6.1 bL = AUTOMATIC BACKLIGHT CONTROL
- 6.2 AVE = DISPLAY AVERAGING RATE
- 6.3 FIL = ADC FILTER RATE
- 6.4 bod = BAUD RATE SELECTION
- 6.5 cont = CONTINUOUS PRINTING
- 6.6 PIECE = PARTS COUNTING
- 6.7 StEPS = CHECK-WEIGHING FUNCTION (LOW-OK-HIGH)
- 6.8 CALIbr = CALIBRATION ROUTINE
- 6.9 rePL = RESULTS PRINTED AUTOMATICALLY OR MANUALLY
- 6.10 StAb = PRINT WHEN STABLE or INSTANTANEOUS
- 6.11 Aut = AUTOZERO FUNCTION
- 6.12 t1 = AUTOMATIC POWER SWITCH OFF
- 6.13 toP = HOLD MAXIMUM VALUE
- 6.14 nE = WEIGH IN NEWTONS
- 6.15 SuPP = Power supply voltage to PCB
- 7.0 COMMUNICATION WITH A COMPUTER/PRINTER
© Adam Equipment Company 2005
8
6.2 AVE = DISPLAY AVERAGING RATE
• It selects the required averaging for the display update.
• Press the [Func] key until AVE is displayed.
• Press [Print] to select the desired value.
• Press the [Func] key to return to weighing.
AVE 1 = Fastest display rate for uses such as filling.
AVE 5 = Slowest display rate for uses such as animal weighing
or poor environment.
• Press the [Func] key to return to weighing.
6.3 FIL = ADC FILTER RATE
• It selects the required filter rate.
• Press the [Func] key until FIL is displayed.
• Press [Print] to select the desired value.
• Press the [Func] key to return to weighing.
FIL 1 = Fastest rate for speed.
FIL 4 = Slowest rate for poor environment.
• Press the [Func] key to return to weighing.
6.4 bod = BAUD RATE SELECTION
• It selects the required baud rate for the RS-232 communications.
• Press the [Func] key until ”bod” is displayed.
• Press [Print] to select the desired value.
bod 1 = 300 Baud
bod 2 = 600 Baud
bod 3 = 1200 Baud
bod 4 = 2400 Baud
bod 5 = 4800 Baud (default)
bod 6 = 9600 Baud
• Press the [Func] key to return to weighing.