Datasheet

Aosong(Guangzhou) Electronics Co.,Ltd
---------------------------------------------------------------------------------------------------------------------
Tell: +86-020-36380552, +86-020-36042809 Fax: +86-020-36380562
http://www.aosong.com
Email: thomasliu198518@yahoo.com.cn sales@aosong.com
Address: No.56, Renhe Road, Renhe Town, Baiyun District, Guangzhou, China
- 5 -
------------------------------------------------------------------------------------------------------------------------------------
Start transmit 1bit data Start transmit next bit data
26-28us voltage-length means data "0"
Host signal Sesnor's signal
Single-bus signal
------------------------------------------------------------------------------------------------------------------------------------
Step 3: AM2303 send data to MCU
When AM2303 is sending data to MCU, every bit's transmission begin with low-voltage-level that last 50us,
the following high-voltage-level signal's length decide the bit is "1" or "0".
Check bellow picture for step 3:
------------------------------------------------------------------------------------------------------------------------------------