Datasheet
bootloader version (ex. 'S110 7.1.0, 0.0').
ATZ
Performs a system reset.
Codebase Revision: 0.3.0
Parameters: None
Output: None
ATZ
OK
ATE
Enables or disables echo of input characters with the AT parser
Codebase Revision: 0.3.0
Parameters: '1' = enable echo, '0' = disable echo
Output: None
# Disable echo support
ATE=0
OK
#Enable echo support
ATE=1
OK
+++
Dynamically switches between DATA and COMMAND mode without changing the physical CMD/UART select switch.
When you are in COMMAND mode, entering '+++\n' or '+++\r\n' will cause the module to switch to DATA mode, and
anything typed into the console will go direct to the BLUE UART service.
To switch from DATA mode back to COMMAND mode, simply enter '+++\n' or '+++\r\n' again (be sure to include the
new line character!), and a new 'OK' response will be displayed letting you know that you are back in COMMAND
mode (see the two 'OK' entries in the sample code below).
Codebase Revision: 0.4.7
Parameters: None
Output: None
Note that +++ can also be used on the mobile device to send and receive AT command on iOS or Android,
though this should always be used with care.
© Adafruit Industries https://learn.adafruit.com/adafruit-feather-32u4-bluefruit-le Page 92 of 211