Datasheet
DESCRIPTION
SWITCHING POWER AC
ADAPTER
SHEET NO.
3 OF 4
VER:
A1
MODEL NO. GEO151UB-6025 PART NO.
C688-13917
3.MECHANICAL
ITEM
SPECIFICATION OR TEST CONDITION
ACCEPTANCE CRITERIA
BENDING TEST
NORMAL TEMPERATURE
NO SHORT CIRCUIT
THE CORD SHALL WITHSTAND WEIGHT OF 200g, SWINGING FROM
NO BREAKAGE OF THE CORD
LEFT TO RIGHT AT AN ANGLE OF 60 DEG. 1000CYCLE TIMES MIN.
S/R SHALL WITHSTAND WEIGHT OF 1N. SWINGING FROM LEFT TO
RIGHT AT AN ANGLE OF 60DEG. 1000CYCLE TIMES MIN.
BENDING SPEED 40CYCLE/MINUTE
VIBRATION
FREQUENCY RANGE:10~55Hz
THERE SHALL BENO
AMPLITUDE:1.5mm
ABNORMALITY ON THE
ACCELERATION: 1G
APPEARNCE STRUCTURE
SWEEP 1 MINUTE FOR X,Y,Z,AXIS EACH
AND OPERATING
4.RELIABILITY
ITEM
TEST CONDITION
ACCEPTANCE CRITERIA
TEMPERATURE UP WITH
TEST AT SURFACE OF THE CASE WITH TYPICAL
TEMPERATURE UP UNDER
TYPICAL LOAD
AC INPUT AND TYPICAL LOAD IN OUTPUT
35 DEGREES
50/60Hz
HI-POT TEST
INPUT TO OUTPUT
NO DAMAGE
GRADUALLY RAISED FROM 0 TO THE 3000Vac AND HELD AT
THAT VALUE FOR 3S,10mA
INSULATION RESISTANCE
INPUT TO OUTPUT,DC 500V
>10MΩ
MTBF
TYPICAL INPUT&FULL LOAD , 25
℃
50000 HOURS
BURN-IN
AT 30
℃
(±10
℃
),NORMAL INPUT VOLTAGE
2~4 HOURS
5.ENVIRONMENT
ITEM
SPECIFICATION OR TEST CONDITION
min. typ. max.
OPERATING
TEMPERATURE
0
℃
40
℃
STORAGE
TEMPERATURE
-20
℃
85
℃
OPERATING HUMIDITY
NON-CONDENSING
5%RH 90%RH
STORAGE HUMIDITY
NON-CONDENSING
5%RH 90%RH