Datasheet
MB85RS64V
32 DS501-00015-4v0-E
■ MAJOR CHANGES IN THIS EDITION
A change on a page is indicated by a vertical line drawn on the left side of that page.
Page Section Change Results
10
• RDID Revised the following description.
“In the RDID command, SO holds the output state of the last
bit after 32-bit Device ID output by continuously sending
SCK clock before CS is risen.”
→“In the RDID command, SO holds the output state of the
last bit in 32-bit Device ID until /CS is risen.”
17
■ POWER ON/OFF SEQUENCE Defined values of tpu and tr at operation voltage.
Min Max Unit Condition
tpu 0.1 ⎯ ms V
DD = 5.0 V ± 0.5 V Operation
0.6 ⎯ ms V
DD = 3.3 V ± 0.3 V Operation
tr 100 ⎯ ms/V V
DD = 5.0 V ± 0.5 V Operation
1 ⎯ ms/V V
DD = 3.3 V ± 0.3 V Operation
18
■ NOTE ON USE
Revised the following description.
“Data written before performing IR reflow is not guaranteed
after IR reflow.”
→“We recommend programming of the device after reflow.
Data written before reflow cannot be guaranteed.”
19
■ REFLOW CONDITIONS AND
FLOOR LIFE
Revised to following description.
[ JEDEC MSL ] : Moisture Sensitivity Level 3 (ISP/JEDEC J-
STD-020D)
■ CURRENT STATUS ON
CONTAINED RESTRICTED
SUBSTANCES
Changed the title and revised the description which refers to
a website.
20
■ ORDERING INFORMATION Changed the Minimum shipping quantity.
1 → ⎯*
Added the following note below table.
*: Please contact our sales office about minimum shipping
quantity.
24
1.2 Tube Dry pack packing specifica-
tions
Changed the location of humidity indicator.