Datasheet
TXB0104
SCES650F –APRIL 2006–REVISED MAY 2012
www.ti.com
THERMAL IMPEDANCE RATINGS
UNIT
D package
(1)
86
GXU/ZXU package
(1)
129
PW package
(1)
113
θ
JA
Package thermal impedance °C/W
RGY package
(2)
47
RUT package TBD
YZT package 90
(1) The package thermal impedance is calculated in accordance with JESD 51-7.
(2) The package thermal impedance is calculated in accordance with JESD 51-5.
RECOMMENDED OPERATING CONDITIONS
(1) (2)
V
CCA
V
CCB
MIN MAX UNIT
V
CCA
1.2 3.6
Supply voltage V
V
CCB
1.65 5.5
Data inputs 1.2 V to 3.6 V 1.65 V to 5.5 V V
CCI
× 0.65
(3)
V
CCI
V
IH
High-level input voltage V
OE 1.2 V to 3.6 V 1.65 V to 5.5 V V
CCA
× 0.65 5.5
Data inputs 1.2 V to 5.5 V 1.65 V to 5.5 V 0 V
CCI
× 0.35
(3)
V
IL
Low-level input voltage V
OE 1.2 V to 3.6 V 1.65 V to 5.5 V 0 V
CCA
× 0.35
Voltage range applied to any A-port 0 3.6
V
O
output in the high-impedance 1.2 V to 3.6 V 1.65 V to 5.5 V V
B-port 0 5.5
or power-off state
A-port inputs 1.2 V to 3.6 V 1.65 V to 5.5 V 40
Input transition
Δt/Δv 1.65 V to 3.6 V 40 ns/V
rise or fall rate
B-port inputs 1.2 V to 3.6 V
4.5 V to 5.5 V 30
T
A
Operating free-air temperature –40 85 °C
(1) The A and B sides of an unused data I/O pair must be held in the same state, i.e., both at V
CCI
or both at GND.
(2) V
CCA
must be less than or equal to V
CCB
and must not exceed 3.6 V.
(3) V
CCI
is the supply voltage associated with the input port.
4 Submit Documentation Feedback Copyright © 2006–2012, Texas Instruments Incorporated
Product Folder Links: TXB0104