Table 15: Data Output Z Registers A and B
Data Output Register Operation
When one or more of the output registers are read, new data cannot be placed in any of the output data registers until all
six data output registers are read. This requirement also impacts DRDY and RDY, which cannot be cleared until new
data is placed in all the output registers.
Status Register
The status register is an 8-bit read-only register. This register is used to indicate device status. SR0 through SR7
indicate bit locations, with SR denoting the bits that are in the status register. SR7 denotes the first bit of the data stream.
SR7
SR6
SR5
SR4
SR3
SR2
SR1
SR0
(0)
(0)
(0)
(0)
(0)
(0)
LOCK (0)
RDY(0)
Table 16: Status Register
Location
Name
Description
SR7 to
SR2
0
These bits are reserved.
SR1
LOCK
Data output register lock. This bit is set when:
1.some but not all for of the six data output registers have
been read,
2. Mode register has been read.
When this bit is set, the six data output registers are locked
and any new data will not be placed in these register until
one of these conditions are met:
1.all six bytes have been read, 2. the mode register is
changed,
3. the measurement configuration (CRA) is changed,
4. power is reset.
SR0
RDY
Ready Bit. Set when data is written to all six data registers.
Cleared when device initiates a write to the data output
registers and after one or more of the data output registers
are written to. When RDY bit is clear it shall remain cleared
for a 250 μs. DRDY pin can be used as an alternative to
the status register for monitoring the device for
measurement data.
Table 17: Status Register Bit Designations