RELIABILITY TEST CONDITION
No. TEST Item Content of Test
Test
Condition
Applicable
Standard
1
High temperature
storage
Endurance test applying the high storage
Temperature for a long time.
70ºC 96hrs ------
2
Low temperature
storage
Endurance test applying the low storage
Temperature for a long time
-20ºC 96hrs -----
3
High temperature
operation
Endurance test applying the electric stress
(Voltage & current)and the thermal stress to the
element for a long time
60ºC 96hrs
------
4
Low temperature
operation
Endurance test applying the electric stress
Under low temperature for a long time
-10ºC 96hrs ------
5
High
temperature/
Humidity storage
Endurance test applying the electric stress(Voltage &
current) and Temperature/
Humidity stress to the element for a long time
40ºC 90%RH
96hrs
6
High
temperature/
Humidity
operation
Endurance test applying the electric stress
(voltage & current)and temperature/
humidity stress to the element for a long time
40ºC 90%RH
96hrs
7
Temperature
cycle
Endurance test applying the low and high temperature
cycle.
-10ºC
→25ºC→60ºC
30min←5min←30min.(1 cycle)
-10ºC/60ºC
10 cycle
------
Supply voltage for logic system = 5V. Supply voltage for LCD system = Operating voltage at 25ºC.
Mechanical Test
Vibration test
Endurance test applying the vibration during
transportation and using
10~22Hz→1.5mmp-p
22~500Hz→1.5G
Total 0.5hour
Shock test
Constructional and mechanical endurance test
applying the shock during transportation.
50G half sign wave 11
msede 3 times of each
direction
Atmospheric
pressure test
Endurance test applying the atmospheric pressure
during transportation by air
115mbar
40hrs
Static electricity
test
Endurance test applying the electric stress to the
terminal
VS=800V,RS-1.5KΩ
CS=100pF, 1 time
Environmental condition
The inspection should be performed at the 1metre height from the LCD module under 2 pieces of 40W white fluorescent
lamps (Normal temperature 20~25℃ and normal humidity 60±15%RH).