User manual

HTR-2400 Manual Page 9
Connections - Rear Panel
IR Emitter Outputs
RS-232
Switch
IR Receiver (Learner)
IRL-5000
IR Learn
Mode
(IRL-5000)
Normal
Mode
(PC Setup
& RS-232
Control)
Source 8 Source 7 Source 6 Source 5 Source 4 Source 3 Source 2 Source 1
SUBWOOFER
SURROUND BACK RIGHT
SURROUND BACK LEFT
CENTER
SURROUND RIGHT
FRONT RIGHT
FRONT LEFT
SURROUND LEFT
Component Video Output
YP
B
P
R
Component Video Input 2
Component Video Input 1
YP
B
P
R
Component Video Input 3
YP
B
P
R
YP
B
P
R
Video
In
Video
Out
e
2 Source 4 Source 6 Source 8
e
1 Source 3 Source 5 Source 7
Room 5
Room 7 Room 3 Room 1 &
Theater
Room 8 Room 6 Room 4 Room 2
S-Video Out
2
1
S-Video Inputs
2
1
4
3
HOME THEATER
RECORDING DEVICEHOME THEATER/ROOM 1
HOME THEATER
The HTR-2400 also features line-level audio outputs for the home theater zone. In many
cases, while you may be using the power amplifier in the HTR-2400 for all of the theater’s
speakers, you may need to use its line-level audio outputs for connection to a self-powered
(active) subwoofer. Alternately, you can connect additional power amplifiers or a multi-chan-
nel power amplifier to the HTR-2400.
ofer Surround
Back
Right
o
rt
RS-232 Port
Theater Trigger
4
1( -) 2 (+ )
D
C
Straight Through
12VDC Output
Set RS-232 Switch
See IRL-5000
u
t
3
S-Video Out
2
1
S-Video Inputs
2
1
4
3
AC
2
AC
1
CAUTION:
Disconnect Supply Cord Before Servicing.
ATTENTION:
Debrancher Avant Le Depannage.
120VAC~
60Hz
1200W
230VAC~
50Hz
1200W
10ASB
115V
5ASB
230V
If Box Red
2 CONDUCTOR
LOW VOLTAGE WIRE
Bypass Trigger
All-On Trigger
230V~ 5 ASB
115V~ 10 ASB
MAIN FUSE
230V~
1/10 ASB
115V~
2/10 ASB
STBY FUSE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
230V
115V
115V
1200
WATTS
MAX
All Channels
12VDC
1(-) 2(+)
-
6
115 V
115 V
12
Home
Theater
Amplified
Audio
Output
7.1 Channels
All Ouputs
8 - 4
Do Not
Short
Outputs!
Do Not
Bridge
Outputs!
Front
Left
+-
Surround
Left
-+
Center
+-
Surround Back
Left
Front Right Surround Right Subwoofer Surround Back Right
-+
+--++--+
AM/FM/WX Radio
(To Input)
AM/FM
Antenna
Input
75
Audio Output
LR
XM Radio®
(To Input)
XM
Antenna
Input
50
Audio Output
LR
+ - - +
LR
Room 1
(8 - 2 )
+ - - +
LR
Room 2
(8 - 2 )
+ - - +
LR
Room 3
(8 - 2 )
+ - - +
LR
Room 4
(8 - 2 )
+ - - +
LR
Room 5
(8 - 2 )
+ - - +
LR
Room 6
(8 - 2 )
+ - - +
LR
Room 7
(8 - 2 )
+ - - +
LR
Room 8
(8 - 2 )
Room Keypad Control Connections Use Any RJ-45 Port ADA Bus® Port
RS-232 Port
Theater Trigger
RJ-45 Ports Are Not Room Specific Cat. 5 Wire Is Straight-Through
1 2 3 4
1( -) 2 (+ )
Gnd +VDCOut In
TX RX
Straight Through
12VDC Output
Set RS-232 Switch
See IRL-5000
Component Video Output
YP
B
P
R
Component Video Input 2
Component Video Input 1
YP
B
P
R
Component Video Input 3
YP
B
P
R
YP
B
P
R
Video
In
Video
Out
Source 2 Source 4 Source 6 Source 8
Source 1 Source 3 Source 5 Source 7
Room 5
Room 7 Room 3 Room 1 &
Theater
Room 8 Room 6 Room 4 Room 2
S-Video Out
2
1
S-Video Inputs
2
1
4
3
IR Emitter Outputs
RS-232
Switch
IR Receiver (Learner)
IRL-5000
IR Learn
Mode
(IRL-5000)
Normal
Mode
(PC Setup
& RS-232
Control)
Source 8 Source 7 Source 6 Source 5 Source 4 Source 3 Source 2 Source 1
Switched AC
2.5 Amp Max
Per Outlet
AC
4
AC
3
AC
2
AC
1
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
CAUTION:
Disconnect Supply Cord Before Servicing.
ATTENTION:
Debrancher Avant Le Depannage.
120VAC~
60Hz
1200W
230VAC~
50Hz
1200W
10ASB
115V
5ASB
230V
If Box Red
2 CONDUCTOR
LOW VOLTAGE WIRE
Bypass Trigger
All-On Trigger
230V~ 5 ASB
115V~ 10 ASB
MAIN FUSE
230V~
1/10 ASB
115V~
2/10 ASB
STBY FUSE
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
230V
230V
115V
115V
1200
WATTS
MAX
Typical Power: 250-600 Watts
Ultimate Max. Power: 1200 Watts
Average Thermal Load: 2048 BTU/Hr
All Channels
12VDC
1(-) 2(+)
PTM-8150
8 Channel Power Amplifer
Warning! Do Not Short Outputs
WARNING! Risk Of Hazardous Energy!
Make Proper Connections.
AVERTISSEMENT! Energie Electrique Dangereuse! Faire Des Connexions
Propres Pour L'Hautparleur. Voir La Notice De Fonctionnement.
CAUTION: Disconnect Supply Cord Before Servicing.
ATTENTION: Debrancher Avant Le Depannage.
+-
OUTPUT 2-16
INPUT
47K
CH
1
-+
OUTPUT 2-16
-+
OUTPUT 2-16
-+
OUTPUT 2-16
-+
OUTPUT 2-16
+-
OUTPUT 2-16
INPUT
47K
CH
2
+-
OUTPUT 2-16
INPUT
47K
CH
3
+-
OUTPUT 2-16
INPUT
47K
INPUT
47K
INPUT
47K
INPUT
47K
INPUT
47K
CH
4
CH
5
CH
6
CH
7
CH
8
115 V
115 V
12
In the event that you are using an external power
amplifier in the Home Theater, the HTR-2400
features a low-voltage trigger output (12VDC)
that can be used to trigger an ADA power ampli-
fier. Using a 2-conductor low-voltage wire, con-
nect the HTR-2400 trigger to the trigger input on
the ADA power amplifier (set the amplifier Trig-
ger Switch accordingly). You will also need to
set the DC Trigger to ON when programming the
HTR-2400 Theater Sources.
The HTR-2400 video
outputs connect to the
Theater’s video display.
The extra S-Video out-
put can connect to a
recording device.
ANALOG AUDIO RECORD OUTPUT
DIGITAL
AUDIO
RECORD
OUTPUT
The HTR-2400 features an analog and digital au-
dio output which track the source playing in the
theater. These can be connected to recording
devices. The analog output only passes analog
sources and the digital output only passes digi-
tal sources.