Manuel de l'usager du Mux IP vers 2xE1 AN-TDM-IP-1 / 2 E1 A E1/T1 over Ethernet Multiplexer User’s Manual AD-net Technology., LTD contents -1- www.hypercable.
Manuel de l'usager du Mux IP vers 2xE1 AN-TDM-IP-1E1/2E1-A E1/T1 over Ethernet Multiplexer User’s Manual AD-net Technology., LTD 2012.03 contents -2- www.hypercable.
Manuel de l'usager du Mux IP vers 2xE1 Disclaimer The information contained in this document is subject to change without notice and does not represent a commitment on the part of AD-net Technology., co LTD (AD-net). The information in this document is believed to be accurate and reliable; however, AD-net assumes no responsibility or liability for any errors or inaccuracies that may appear in the document. Copyright 2012 by AD-net Technology., co LTD All rights reserved.
Manuel de l'usager du Mux IP vers 2xE1 TABLE OF CONTENTS 1. GENERAL...........................................................................................1 1.1 1.2 1.3 1.4 2. OVERVIEW ............................................................................................1 FEATURES .............................................................................................1 APPLICATIONS .......................................................................................1 TIMING MODES .......
Manuel de l'usager du Mux IP vers 2xE1 5.3.1 Alarm Shielding Management .....................................................16 5.4 ETHERNET MANAGEMENT....................................................................16 5.4.1 Ethernet Management .................................................................17 5.4.2 Ethernet Senior Management ......................................................18 5.4.3 VLAN Management .....................................................................19 5.
Manuel de l'usager du Mux IP vers 2xE1 www.hypercable.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD General 1. 1.1 Overview Thank you for selecting the AN-TDM-IP-1E1/2E1-A E1/T1 over Ethernet multiplexer product designed and made by AD-net Technology., LTD The product adopt the innovative TDM over IP technology, with IP circuit emulation that supports transportation of 1~2 E1 /T1 over FE port, that can be used to provide E1 communication channels over Ethernet or IP networks.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD multiplexer AN-STM-1-IP, make point-to-multipoint application ,and point of connection, Typical application is shown in Fig 1.3-1~Fig 1.3-3. point to Figure 1.3-1 Convergent Application Figure1.3-2 Typical application of wireless network Fig. 1.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD destination accurately. Packet networks do not provide such built-in timing transparency mechanism as TDM networks do. AN-TDM-IP-1E1/2E1-A uses its proprietary algorithm to reconstruct the E1 clock at the destination. The recovered clock is of very high quality, with low jitter and wander. Typical frequency offset is within ±5ppm, and jitter is below 0.1UI. It can be adopted in most applications.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD Various timing schemes are listed in Table 1.4-1, for applications depicted in Fig.1.4-2. Fig.1.4-2 Timing mode scheme reference diagram Table 1.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD 2.2 Structure AN-TDM-IP-1E1/2E1-A adopt standard 1U box (W x H x D: 195 mm×35 mm×140 mm), which is composed by system board and power supply card. AN-TDM-IP-1E1/2E1-A system structure is shown in Fig 2.2-1: Fig 2.2-1 AN-TDM-IP-1E1/2E1-A system structure 2.3 Front panel 2.3.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD 2.3.2 LED’s The definition is shown in Table 2.3.2-1: Table 2.3.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD 2.3.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD OFF: use the user’s Setting IP address There are 4 group dips on the bottom of panel, used for controlling the E1 / T1 interface impedance and 75 Ω unbalanced interface shell grounding, as the Table 2.3-3. Table 2.3-3 Dip Switches Definition of bottom panel Dip One Two Three (only SA1602 support ) Four (only SA1602support ) 2.3.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD Adopt 75Ω E1/T1 unbalanced interface, can be used for BH4.815.122 conversion cable which convert RJ45 to BNC connector. Fig 2.3-6 75Ω dedicated cable E1/T1 interface provide Rx Tx、 Tx Rx loop back operation through network management , it is convenient for operating and maintain test . 2.3.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD Pin 1 2 Definition TxD+ TxD- 3 4 5 RxD+ 6 7 8 RxD- Note: 1. At auto-negotiation mode, Ethernet electrical port supports HP auto-MDIX function and it can check the transmission and receiving sequence and make configuration. So both MDI and MDI-X interfaces are supported and both cross line and direct line can be selected. 2. Network Management can be used for all the Ethernet ports except Data1 port.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD 3.2 Ethernet/optic fiber connections AN-TDM-IP-1E1/2E1-A provides four 100Base-Tx Ethernet electrical interfaces (two ports are uplink ports used to connect with transmission network and the other two are local data ports used to connect with local Ethernet), and one 100Base-Fx optical interface used as either uplink port or local Ethernet port such as switch.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD complete plugged in or not connected with, please check the following subject: the power supply to meet the requirements or not, the power plug is connected, the switch is open. 4.1.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD 4.1.6 TWO ENDS DEVICES CANNOT CONNECT Both sides of devices in the same Ethernet broadcast domain, checking both side of device IP address should on dual relationship. Check MAC address is unique (include other device on the same network); Using Ping command to check network, checking bandwidth is sufficient or not.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD All Web Server include 7 parts: System Info, Alarm Status, Alarm Management, ETH Management, E1 Management, SNMP Management, and System. Following will introduce AN-TDM-IP-1E1/2E1-A. the Web Server Management of 5.1 System Info After login Web Server, will show Welcome page. In this page include Hardware version number, Software version number, Web manager version number, IP address, Subnet Mask, Gateway IP address, MAC address.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD 图 5.2-1 E1 Alarm Status 5.2.2 Ethernet Port Status Click Left side Alarm Status – ETH Port will show 4 Ethernet electrical ports and 1 optical port LINK UP/DOWN stats, as shown in Fig5.2-2. Fig 5.5-2 ETH port Alarm Status 5.2.3 Power Status Click left side Alarm Status – Power Status will show Power Alarm Status, include 2 power ad Status information, as shown in Fig 5.2-3. Fig 5.2-3 Power Status 5.2.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD 5.2.5 BER Test Click BER Test will show picture as below, include BER Enable, Testing Port, Start and Stop, Port Status (Frame synchronization or Frame Desynchronization), Bit Error Rate and Error timing, as shown in Fig 5.1-5. If you need test Error for one link, first you should click “enable” and “start”, and click “Submit”, Web Server will show result. During Testing click “Refresh” will show result of now status. Fig 5.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD (MAC address aging time, QoS management and port Throughput limiting) and VLAN management. 5.4.1 Ethernet Management Fig.5.4-1 Ethernet Management Table 5.4-1 Ethernet management parameters Parameters Options Port Service No. Link Speed Ethernet Management Duplex Explanation 5 Ethernet ports number Ethernet service No.: support at most 15 capital/small letters, digit and part special character input.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD 5.4.2 Ethernet Senior Management Ethernet senior management supports MAC address aging time, Ethernet port QoS management and throughput limiting. MAC address aging time range is 0~99999 s (default: 300s). Fig 5.4-2 Ethernet management For Ethernet interface 1~5, we can enable QoS (based on port, 802.1p and TOS) Fig 5.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD 5.4.3 VLAN Management Two uplink Ethernet electrical interfaces support 1+1 protection. After enabling 1+1 protect, equipment configure Q in Q VLAN automatically and user only need to configure VID of uplink Ethernet electrical interface and monitoring port. As shown in Fig 5.4-5 and Fig 5.4.6. Fig 5.4-5 uplink 1+1 protect configuration Fig 5.4-6 configure Q in Q VLAN automatically AN-TDM-IP-1E1/2E1-A Ethernet supports 802.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD Fig 5.4-9 VLAN management 3—Ethernet port configuration Fig 5.4-10 VLAN management 4—VLAN Table Fig 5.4-11 VLAN management 5—VLAN configuration confirmation Table 5.4-3 VLAN management parameters Parameters VLAN Mode Options Disable No VLAN tag 802.1Q Add the VLAN tag before Ethernet frame type. Q in Q Protection Control Service Protection Attribute Ethernet Port E1 Channel - 20 - Explanation Add operators VLAN (S-Tag) in 802.1Q.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD Parameters VLAN Configuration Options VID Priority Eth Name Ethernet Port VLAN Configuration VLAN Table Explanation VLAN ID, support 4094 VLAN, ID, range (1-4094) Define customer priority, including 8 PRI degrees (0-7). PRI is higher when this number is bigger. Ethernet port number 1~5. VLAN ID, support 4094 VLAN, ID, range (1-4094) Define customer priority, including 8 PRI Priority degrees (0-7).
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD 5.5.2 E1 Senior Management Fig 5.5-2 E1 channel senior Management Fig 5.5-3 TTL/TOS configuration of E1 channel Management Table 5.5-1 E1 Management parameters Parameters Service Name Selections Enable this E1 channel.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD Parameters Encapsul ation Selections IPv4_UDP 1×128 byte 2×128 byte Frame Size 4×128 byte Advanced Enable RTP Disable TTL/TOS Explanations IP Encapsulation Every Ethernet packet encapsulation length can select 1×128/2×128 字节/4×128 byte. The longer the packet is, the more E1 data encapsulated in the packet, the lower expense ratio is, the higher bandwidth efficiency is and the bigger time delay is. Vise versa.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD Parameters Option SNMP Write Community SNMP Trap Community SNMP Port Number SNMP Trap Address SNMP Trap Address and Port SNMP Trap Port Explanations Configure commands of device nodes Default: private Receive commands of Trap Default: public The communication ports connecting the devices with SNMP, SNMP protocol, Default: port: 16 Address used to receive Trap information: The most addresses and ports can be set is up to 5.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD SNMP management includes SNMP server option (stop/start/test), time setting interval (10~60000 minutes), SNMP server IP address and SNMP server status display (disable/enable, connect successfully/fail). Note: It needs to get the current time again once the power is off. 5.7.2 Change the password Fig 5.7-2 Change the password The change will be valid after confirm the submitting. 5.7.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD Fig 5.7-4 generate configuration code Step 2. Input the configuration code and click Submit. Fig 5.7-5 change E1/T1 port number Step 3. Check the E1/T1 number in Configuration Status to confirm whether the change is successful. Fig 5.7-6 change is successful 5.7.4 Upgrade online Both AN-TDM-IP-1E1/2E1-A hardware and software program can be upgraded by ftp. Following will introduce Web Server upgrade online operation.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD upgrade program to the server, as figure 5.7-7. Note: Hardware program file name is H_Patch.r, and software program file name is S_patch.r. The file name cannot be changed. Fig 5.7-7 upgrade online 1—upload upgrade program Step 2: Select program type (it is available to select software and hardware at the same time) and click Upgrade to start. Fig 5.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD Fig 5.7-10 upgrade online 4—operate successfully Note: If the power is off during upgrade, it may make equipment not start and need to program procedures with download line. 5.7.5 Reboot system Fig7.7-11 Reboot equipment 6. Specification 6.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology., CO LTD H0FL-AN-TDM-IP SA1602: 2 E1/T1 ports 6.3 Ethernet Port Comply with IEEE 802.3、802.1Q、802.1ad、802.1P and relative other protocol. Operating Mode:10M/100M Adaptive, Half/Full Duplex Adaptive MTU: 9720byte Connector:100M Electrical port: RJ45 100M Optical Port: LC Interface no.: 100M Electrical Port:4 100M Optical Port: 1 6.4 Power AC: 100V~260V/50Hz ~60Hz (fuse: 1A) DC: -36V ~ -72V Power Consumption: ≤4W 6.
Manuel de l'usager du Mux IP vers 2xE1 AD-net Technology. CO LTD 7. Appendix Specialized terminologies and acronyms: Acronym TDM - 30 - Explanations Time Division Multiplex SAToP Structure-Agnostic TDM over Packet DSCP Differentiated Services Code point UDP User Datagram Protocol QoS Quality of Service TOS terms of service TTL Time To Live VLAN Virtual Local Area Network RTP Real-time Transport Protocol SNTP Simple Network Time Protocol www.ad-net.com.tw www.hypercable.