1.4. Package content
The appliance is transported in carton box with internal protective elements.
The package contains the following:
Installation, usage and maintenance manual 1 item
Y filter Rp3/4 1 item
Flexible conduit to discharge condensate water 1 item
Feet fixing 3 items
Drill frame 1 item
Wire installation rubber 1 item
1.5. Transport and handling
During product delivery, please check that there is no visible damage on the
external part of packaging. If the product seems to be damaged, please turn to the
delivery company with your complaint in no delay.
Similar to all equipment containing a compressor, the heat pump must be
stored and transported only in a standing position (see Figure 1.5.-1.)
WARNING!
The appliance must be transported, handled or stored in a vertical position
and it must not be inclined more than 45° (Figure 1.5.-2.). This appliance is very
heavy, it needs to be carried by 2 or more persons, otherwise it might cause
personal injury or appliance damage. If during any of the operations above, the
placement of the appliance needs to be different from the recommended position,
before the first start up of the appliance, please wait at least 3 hours starting from
the time when the appliance has been put into the proper vertical position and / or
into operation. This way, it is ensured that the lubricating oil working within the
cooling circuit is placed properly and compressor damage is avoided.
The packaged appliance can be handled by hand or by lift truck – please
follow the instructions printed on the carton box.
It is recommended to keep the appliance in the original packaging until it is
installed on the selected place, if possible, especially when construction work is
performed on the site.
During the removal of the package, please check that the appliance is intact and all
necessary parts are placed in the package. In case of any deficiency or missing
parts, please notify the contracted distributor within the deadline defined by law.
WARNING!
Due to potential danger, please keep packaging material (clips, plastic sacks, polystyrene foam)
away from children.
During handling or transportation of the appliance after its first start up, please keep warnings on
maximum inclination angle described above and ensure that all water has been discharged from the tank. If the
original packaging no longer exists, please provide protection to the appliance and its parts similar to the
original packaging.
2. TECHNICAL FEATURES
2.1. Operation principle
HB300(C) heat pump water heater is seemingly similar to traditional electric hot water tanks. During its
normal operation cycle, HB300(C) connected to household pipeline and electrical power system does not use as
much electric power for direct heating of water as the traditional electric hot water tank does, but rather, it uses
energy in a more rational and efficient way, reaching the same result with an energy use of less than 70% as
compared to the traditional electric hot water tank.
Heat pump is named by the fact that it is able to transfer heat from a heat source of lower temperature to
a heat source of higher temperature, which means it turns natural flow of heat, which is transferred from a heat