Operation Manual

Figure 7.1.-5.
a)
The selected location must be ready to house a discharge opening for condensate water connected to the
upper part of the appliance with a flexible circuit.
b)
Please ensure that the location of operation and electric and hydraulic systems to which the appliance
will be connected fully comply with all relevant regulations.
c)
The selected location has to possess (or to be able to house) a single phase 230 V ~ 50 Hz external
switch.
d)
According to the definitions of relevant regulations, the selected location has to comply with IP
protection class (protection against liquid penetration).
e)
Do not expose the appliance to sunlight, not even through any window.
f)
The appliance must not be exposed to effects of especially aggressive materials, i.e. acidic gases,
environment saturated by dust or gas.
g)
The appliance must not be mounted directly to phone line without overvoltage protection.
h)
The appliance must be placed and operated as close to the usage points as possible, in order to limit the
diffusion of heat along the pipeline.
i)
Adequate electric power system, water pipeline and sewage system should be ensured on the location of
the operation. (floor drain).
j)
In order to reduce heat loss due to hot water pipe, please install the appliance close to hot water usage
locations, if possible. In case of larger distances, it is rational to equip the hot water pipe with heat
insulation.
k)
Unused connection branches of the hot water tank must be closed and equipped with heat insulation. .
l)
Review measure diagrams (Figure 2.8.-1.)
EN 28