Specifications

RATE OF FLOW
PRESSURE REDUCING
114R (Globe) / 1114R (Angle)
RATE OF FLOW (“R” indicates over the seat flow)
Maintains a constant flow rate, adjustable, regardless of fluctuations
in line pressure. The rate of flow pilot senses the differential pressure
across a thin edged orifice plate mounted in the valve inlet flange. It
responds to changes in pressure and modulates the main valve to
maintain the desired flow.
SPECIFY:
Desired flow rate at time of order.
ACV 114R: flow over the seat (fail closed)
ACV 114: flow under the seat (fail open)
Additional combination functions:
114-1R Rate of Flow / Solenoid On-Off
114-2R Rate of Flow / Pressure Reducing
114-8R Rate of Flow / Pressure Sustaining
QUICK SIZE: Stay within parameters of capacity chart (below)
Points to consider:
– Orifice plate sized per application and per your
acceptable pressure drop - consult factory
VALVE FUNCTION
Limits flow rate to a constant preset maximum (adjustable)
COMPONENTS
1. Main Valve
2
. Flow Control Pilot
3. Needle Valve - Adj. Closing Speed
4. Orifice Plate
ACCESSORIES
Located as indicated AOS - Adj. Opening Speed
Included as marked X - Isolation Cocks
Y - Y Strainer
FC - Flo-Clean Strainer
P - Position Indicator
L - Limit Switch
115 (Globe) / 1115 (Angle)
PRESSURE REDUCING
Automatically reduces a higher inlet pressure to a constant lower
outlet pressure regardless of changing flow rate and/or varying inlet
pressure. Refer to ACV 115-7 for dead-end systems and/or systems
using high demand, on-off equipment.
NOTE:
Adjustment range:
Standard: 20-175 psig
Optional:
0-30 psig
100-300 psig
(stainless steel control)
Remote sense: ACV 115-1
QUICK SIZING:
Valve size one size smaller than line.
Points to consider:
– See Engineering Data - Pressure Reducing Sizing
Check maximum and minimum flow
Check pressure drop - pressure reducing valves or cavitation chart
If valve size required is smaller than line size, consider ACV 6115
Consult Watts ACV representative/factory
VALVE FUNCTION
Reduce higher inlet pressure to constant lower outlet pressure (adjustable)
COMPONENTS
1. Main Valve
2. Pressure Reducing Control
3. Fixed Office
4. Adj. Opening Speed (3” and Smaller)
ACCESSORIES X - Isolation Cocks
Located as indicated Y - Y-Strainer
Included as marked P - Position Indicator
FC - Flo-Clean Strainer
L - Limit Switch
ACS - Adjustable Closing Speed
VALVE SIZE – INCHES 2 2 1/2 346 810 12 14 16
MINIMUM FLOW RATE
15 35 35 50 115 200 300 400 500 850
GPM
MAXIMUM FLOW RATE
208 460 460 800 1800 3100 4900 7000 8500 11000
GPM
ACV 114 VALVE CAPACITY CHART
(Normal Continuous Flow Based on 20 ft/ per Second)
Flow Direction Shown: Over the Seat
Flow Direction Shown: Under the Seat
Optional ‘RFlow Over the Seat: 115R/1115R
12