Troubleshooting guide
SETUP
MILLPWR
®
Operation Manual
7-22
• Highlight the “Z-axis Travel” field.
• Move the quill up until you have reached the position where you
want the top travel limit set. Make sure FTO position is located.
• Press the
SET TOP LIMIT softkey.
• Move the quill down until you have reached the position where you want the bottom
travel limit set. Make sure FTO position is located.
• Press the
SET BOTTOM LIMIT softkey.
• Press the
USE key.
• Continue with Setup or press the
USE NEW SETTINGS softkey.
You may
change your
table travel lim-
its at any time.
With the error checking feature enabled, MILLPWR can detect scale miscounts and
record them in the Error Log.
MILLPWR will stop the program if a scale miscount is
detected.
Error Checking
T
o enable/disable the error checking feature:
• From Installation Setup, highlight “Error Checking”
and press
ENTER.
• Press either the
ENABLE or DISABLE softkey.
• Press the
USE key.
• Continue with Setup or press the
USE NEW
SETTINGS
softkey.