Troubleshooting guide

SETUP
MILLPWR
®
Operation Manual
7-22
Highlight the “Z-axis Travel” field.
Move the quill up until you have reached the position where you
want the top travel limit set. Make sure FTO position is located.
Press the
SET TOP LIMIT softkey.
Move the quill down until you have reached the position where you want the bottom
travel limit set. Make sure FTO position is located.
Press the
SET BOTTOM LIMIT softkey.
Press the
USE key.
Continue with Setup or press the
USE NEW SETTINGS softkey.
You may
change your
table travel lim-
its at any time.
With the error checking feature enabled, MILLPWR can detect scale miscounts and
record them in the Error Log.
MILLPWR will stop the program if a scale miscount is
detected.
Error Checking
T
o enable/disable the error checking feature:
From Installation Setup, highlight “Error Checking”
and press
ENTER.
Press either the
ENABLE or DISABLE softkey.
Press the
USE key.
Continue with Setup or press the
USE NEW
SETTINGS
softkey.