Troubleshooting guide

SETUP
MILLPWR
®
Operation Manual
7-15
To start the job clock:
From Setup, highlight “Job Clock” then press the ENTER key.
Press the
START softkey, and the job clock will begin.
T
o stop the job clock:
From Setup, highlight “Job Clock” then press the ENTER key.
Press the
STOP softkey, and the job clock will stop. The job clock’s current time will
be added to the value in the“Elapsed Time” field.
To restart the job clock, press the
START softkey.
T
o reset the job clock and the “Elapsed T
ime” field:
From Setup, highlight “Job Clock” then press the ENTER key.
Press the
RESET softkey, and the job clock and “Elapsed Time” field will be cleared.
Job Clock
Note: The maximum
amount of time that the
job clock will record is
99 hours, 59 minutes
and 59 seconds. The
value will then roll
over to zero and con-
tinue counting.