Specifications

A variety of mounting conditions can be accommodated.
The machine configuration determines the brackets required to
install the linear encoder.
Three typical mounting conditions are shown; flush, offset, and
backup spar (as shown previously on page 4).
The 8-32 SHCS fastener lenghts shown on this page are typical
to the trim length requirement of the 1” long fastener supplied.
The 8-32 SHCS for mounting the reading head is a standard low
head style fastener.
Mounting surfaces are offset.
Installation without backup spar.
Use leveling screws in place of spacers or shims.
Mounting surfaces are flush within .005”.
The reading head leveling screws are not required.
Flush or offset mounting surfaces with a backup spar.
Bracket used to reduce head to mounting surface gap.
Use reading head leveling set screws.
ACU-RITE
®
8
Typical Mounting (s) ENC 150
Backup spar with
bracket
Offset surfaces
1/4-20 x 1” BHCS
and encoder washer
8-32 x 3/4” SHCS (trim)
Flush surfaces
.005
0.0 ± .005
1/4-20 x 1” BHCS
with encoder washer
8-32 x 1” SHCS
Space of < .18” use reading head
leveling set screws.
1/4-20 x 1/2” BHCS
and spar washer
8-32 x 5/8” SHCS
(trim)
1/4-20 x 1/2” BHCS
and washer
A space >.18”, use a spacer or
bracket (shown); <.18” use