Specifications

Slide the brackets away from the reading head.
Remove the alignment brackets and save for future use.
Proceed to page 13, “Checking Your Installation”.
Drill / tap the first end mounting hole / attach the linear encoder.
Align to within .010” TIR. to -A-, drill / tap second end hole.
Attach the linear encoder / align to within .010” TIR. to -A-.
Center the axis and mark the reading head mounting holes.
Move axis, drill / tap holes for 8-32 (M4).
Attach head to axis / Set leveling screws / Secure fasteners.
Use the center support(s) when provided.
Place supports at equal intervals along the encoders length.
Center support
Alignment bracket
removal
Slide brackets away from reading
head and cable.
twist 45°
-A- = Axis travel
1/4-20 x 1” BHCS & Scale flat washer
(M6 x 25mm)
Align to within .010” TIR
to -A-
Drill / tap
for 1/4-20 (M6).
8-32 x 3/4” SHCS
(M4 x 20mm)
Do not tighten prior to adjusting
leveling set screws.
Drill / tap for 8-32 (M4).
ACU-RITE
®
10
Encoder Installation Procedure ENC 150
1/4-20 x 3/4” SHCS
(M4 x 20mm)