Do the following service codes and procedures:
• Code 33
Software Identification. This is needed if you call SWI Customer Service.
• Code 313 Configuration Values
• Code 123 Calibration Mode.
Possible Cause Check This
Configuration file corrupt Load default configuration by going to code 313
Not saving Calibration values Replace Computer/Pendant module.
See Computer/Pendant
If calibration factors are being saved, but the measurements are not repeating or are not accurate:
• See Measurements Are Not Repeating
• See Measurements Are Not Accurate
3.3.10 Auxiliary Functions Not Working (Option on 3 Axis
Machines Only)
The Auxiliary Functions will not turn on or off at the programmed times. There are 3
Auxiliary Functions:
1. Activates or deactivates a "110VAC Receptacle" typically used for a coolant pump or
solenoid for mister.
2. Sends an electrical signal to rotate the turret on a "Haas Indexer".
3. Turns the "Spindle Off" at the end of a programmed event. (Note: This function is
not available for retrofits.).
In order to run the above auxiliary functions in run mode, the accessory key on the front
of the pendant must be in the AUTO mode. Press and hold to activate AUTO mode.
All of the auxiliary function signals are carried down to the cable breakout box through
umbilical #2. Each function then has its own relay inside this box. If one of these relays
fail then these features will not work.
Do the following service code and procedures:
• Code 33 Software Identification. This is needed if you call SWI Customer Service.
Possible Cause Check This
Bad 110VAC "Coolant or solenoid"
receptacle fuse
Check if the fuse light indicator next to the plug is lit.
Verify that the fuses are good or bad by checking the
resistance of the fuses using an Ohmmeter.
Poor cable connections
Check all the cable connections on the cable
breakout box, Coolant Pump, and Air Solenoid
(Located on the Air Regulator). In particular, check
umbilical # 2 cable, which carries the auxiliary
function signals.
Faulty "Indexer" connector
Check for continuity between pins 3 and 4, when the
output of the Haas Indexer connector is activated.
Bad cable breakout box
Check 110 V power coming out of the AC E-stop port
with the E-stop in the out position. This will cause
the spindle to not run.