Specifications

Southwestern Industries, Inc.
ProtoTRAK SMX K2, K3, K4 & Retrofit Safety, Installation, Maintenance, Service & Parts List Manual
138
Caution!
For the X-axis, make sure the drain tube is removed from the path of the TRAK Sensor. A
crash of the sensor will break the Sensor or mounting base. Install the drain plug provided
to discourage the re-attachment of the drain tube.
7.6 TRAK Sensor Installation - Optional
See Section 5 of this manual for more sensor information.
Parts required:
Sensor M250C
X Y bracket kit, one of the following:
15926 16191
15927 15929
16105
7.6.1 X and Y Axis Sensor
1. Install the brackets and run bar to the machine. The bracket should position the TRAK
Sensor so that it is:
As low as possible on the back of the table
Does not run the gage wheel over the drain hole or any other existing holes in the
table.
Does not run the gage wheel off the end of the table.
Clears the machine column when the saddle is cranked all the way back and the knee
is lowered.
Figure 59
X Bracket Installation