User's Guide

Rev. 1
HEXAPAD 10 BC USB
8.5.4.10 gen2target - EPC Tagert tagert
Command
gen2target value
Function
Check (no value) or change the "Target" parameter of the Gen2 pattern.
Description
It is the flag of each tag session.
Pattern
the
Values
the
Reading session flag tags in state A.
b
Reading session flag tags in state B.
Ab
Reading flag tags from the session in state A, then in B.
Ba
Read tags with session flag in state B, then in A.
Notes
The combination of gen2session and gen2target values reflects the read repetition rate of
the same tag.
Example
To check the Target value:
gen2target<CR>
a<CR>
To change the target value to ab:
ab<CR gen2target>
ok - parameter has been changed.<CR>
Errors
When the value reported is not among the specified:
error - value out of range<CR>
When more than one value is passed to the command:
error - too many args.<CR>