User's Guide

Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid
Rev. 13
Copyright © 2022 Acura Technologies
73 de 92
10.3.10 Configuring GPIO
TMFTDB
SET/GET
Changes or checks the time in milliseconds when the reader's digital input signal
must remain enabled for the read operation to fire in trigger mode. Values from 0 to
1000ms.
Note: You do not need to reboot the reader.
Example:
Direction
Description
$ SET TMFTDB=500<CR>
Host →
Reader
Host sends the message to
change the debouncing time
to 500ms.
$ OK<CR>
Host ← Reader
Reader responds with OK,
successful change.
Configuring GPIO (continued):
INVINPT
SET/GET
Changes or checks the option to reverse the trigger signal trigger trigger logic.
Values [ON, OFF].
Note: You do not need to reboot the reader.
Example:
Direction
Description
$ SET INVINPT=ON<CR>
Host → Reader
Host sends the message to reverse the
logic of triggering the reader's digital input.
$ OK<CR>
Host ← Reader
Reader responds with OK.
INPUT0
GET
Checks the logical state of the reader's digital input (ISO IN). Values [0 and 1].
Note: You do not need to reboot the reader.
Example:
Direction
Description
$ GET INPUT0<CR>
Host → Reader
Host sends the message to check the
logical state of the digital input.
$ 0<CR>
Host ← Reader
Reader responds with 0, low level.
OUTPUT0
OUTPUT1
SET/GET
Changes or checks output output from the OUTPUT0. Values [0 or 1] high or low
level, [~] to reverse the logical state of the output and [ * ] to trigger the pulse of
the laser.
Note: Parameter used only when the communication interface type is None.
Example:
Direction
Description
$ SET OUTPUT0=0<CR>
Host →
Reader
Host sends the message to configure
the OUT0 output to turn off ther
andlé.
$ OK<CR>
Host ← Reader
Reader responds with OK.
$ SET OUTPUT0=1<CR>
Host →
Reader
Host sends message to set out out0
output to turn on the reins.
$ OK<CR>
Host ← Reader
Reader responds with OK.