User's Guide
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid
Rev. 13
Copyright © 2022 Acura Technologies
70 de 92
Setting Reading (continued):
SELFTMSK
SET/GET
Changes or checks the value of the mask that the Id must contain to be read. Values
allowed hexadecimal characters of a maximum of 24 digits.
Note: You do not need to reboot the reader.
Note: Parameter used only when autoid system type is Normal.
Example:
Direction
Description
$ GET SELFTMSK<CR>
Host →
Reader
Host sends the message to read the
mask value.
$ 123456789ABC<CR>
Host ← Reader
Reader replies that the value is 3s.
$ SET SELFTMSK=00AABB<CR>
Host →
Reader
Host sends the message to change
the value of the mask, that is, only
tags with this mask value starting in
the digit configured in SELFTDG will
be read by the reader.
$ OK<CR>
Host ← Reader
Reader responds with OK.
SELFTDG
SET/GET
Changes or checks the value of the initial digit at which the mask provided above
starts in tag Id. Values allowed 0 to 24.
Note: You do not need to reboot the reader.
Note: Time used only when more than one tag is read at the same time.
Example:
Direction
Description
$ GET SELFTDG<CR>
Host →
Reader
Host sends the message to read the
mask value.
$ 0<CR>
Host ← Reader
Reader replies that the value is 0.
$ SET SELFTDG=5<CR>
Host →
Reader
Host sends the message to change
the digit value to 5, that is, only tags
with that mask value starting at digit
5 will be read by the reader.
$ OK<CR>
Host ← Reader
Reader responds with OK.