User's Guide
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid
Rev. 13
Copyright © 2022 Acura Technologies
69 de 92
$ SET SNDOPT=DRIVER<CR>
Host →
Reader
Host sends the message to change the
parameter.
$ OK<CR>
Host ← Reader
Reader responds with OK.
IDERR
SET/GET
Changes or verifies the id that will be sent when an associated vehicular tag is
identified by the reader, and the driver tag associated with the car tag has not been
identified. The Id value must be a maximum of 8 characters and in hexadecimal
format.
Note: You do not need to reboot the reader.
Note: Parameter used only when the autoid system type is secure.
Example:
Direction
Description
$ GET IDERR=99999999<CR>
Host →
Reader
Host sends the message to change the
value of the binding error id.
$ OK<CR>
Host ← Reader
Reader responds with OK.
IDERRTM
SET/GET
Changes or checks the wait time in seconds to send the error id configured in
"IDERR". Values allowed from 3 to 60s.
Note: You do not need to reboot the reader.
Note: Parameter used only when autoid system type is safe.
Example:
Direction
Description
$ GET IDERRTM<CR>
Host →
Reader
Host sends the message to read the
time value.
$ 3<CR>
Host ← Reader
Reader replies that the value is 3s.
$ SET IDERRTM=10<CR>
Host →
Reader
Host sends the message to change the
value to 10s, that is, when an
associated vehicular tag is identified,
the reader will try for 10s to read the
driver tag associated with the car tag.
$ OK<CR>
Host ← Reader
Reader responds with OK.