User's Guide
Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid
Rev. 13
Copyright © 2022 Acura Technologies
61 de 92
STATCONN1
STATCONN2
GET
Checks the connection status of the data communication port.
Example:
Direction
Description
$ GET STATCONN1<CR>
Host →
Reader
Host sends the message.
$ DISCONNECTED<CR>
Host ← Reader
Disconnected port.
$ GET STATCONN2<CR> Host → Reader Host envied a message.
$ CONNECTED 192.168.0.84:63344<CR> Host ← Reader Connected to IP:PORT.
RFSTAT
GET
Checks at the time of command execution what the status of the reader's RF
channel is, whether it is transmitting [ON] or idle [OFF].
Example:
Direction
Description
$ GET RFSTAT<CR>
Host →
Reader
Host sends the message.
$ ON<CR>
Host ← Reader
O canal RF está transmitindo.
$ GET RFSTAT<CR> Host → Reader Host sends message.
$ OFF<CR> Host ← Reader The RF channel is idle.
Checking the status of the reader (continued):
TGPRSNT
GET
Checks for the presence of a tag being read by the reader, [ON] there is a tag
present, and [OFF] there is no tag present.
Example:
Direction
Description
$ GET TGPRSNT<CR>
Host → Reader
Host sends the message.
$ ON<CR>
Host → Reader
There is a tag present, being read.
$ GET TGPRSNT<CR> Host → Reader Host sends the message.
$ OFF<CR> Host ← Reader No tag present.
NTPSYNC
GET
Checks the last status of the internal bed clock synchronization attempt with the SNTP
server, returns [OK] for success, and [FAILED] for error in automatic adjusting the
reader clock.
Example:
Direction
Description
$ GET NTPSYNC<CR>
Host → Reader
Host sends the message.
$ OK<CR>
Host ← Reader
The clock has been successfully
synchronized.
TEMPMOD
GET
Verifica a temperatura interna do leitor.
Example:
Direction
Description
$ GET TEMPMOD<CR>
Host → Reader
Host envia a mensagem.
$ 44<CR>
Host ← Reader
Internal temperature 44°C.