User's Guide

Guia de usuário Edge-30R+ Autoid / Edge-30R-N+ Autoid
Rev. 13
Copyright © 2022 Acura Technologies
52 de 92
Read parameters (continued):
Parameter
Description
Reading power
Power in centidBm (dBm / 100) referring to tag reading.
The read power can be adjusted to change the read region of tags at the
installation location.
Factory configuration: 3000dBm | Values: 500 to 3000 centidBm (5 to
30 dBm).
Filter by tag signal level
The signal level of the tag indicates whether the tag is near or away from
the antenna, when closer to the antenna, the stronger the RSSI (closer to
zero) and vice versa. If a value is specified for the filter, only tags with RSSI
equal to or greater than that specified will be reported by the reader.
The signal level of the tag is measured in dBm and is a negative value, the
power in Watts is always less than 1mW.
Note: To disable the filter, simply leave the field empty.
Note: The specified value should not contain the minus sign.
Factory setting: Empty (filter disabled) | Values: 20 to 99|dBm| (-20 to -
99dBm).
Filter by reading
tags that contain
on your id the mask
Is the mask value that the tag id must contain to be read, if this field
contains some value, the reader will read only tags that contain this mask
from the given digit.
Note: Parameter used only when the "Autoid System Type" is "Normal or
Hybrid".
Factory configuration: empty, unfiltered | Values: hexadecimals max.
24 digits.
Initial digit of the
mask in tag ID
Is the starting digit in which the mask provided above starts in the tag id.
Note: Parameter used only when the "Autoid System Type" is "Normal or
Hybrid".
Factory configuration: 0 | Values: 0 to 24.