10.2.4 Setting Up Reading
1. After login, click Read.
1. Change the parameters.
2. Click Apply to save the changes.
3. If you see the message prompting you to restart the reader, click Restart.
Reading Parameters:
Parâmetro
Descrição
Reading Mode
Read operation mode that will be performed by the reader.
Continuous mode: Operation mode where the reader performs read
operations continuously.
Trigger mode: Operation mode where the reader performs read operations
only when it receives a signal from a sensor through its digital input.
Factory Setup: Continuous Mode
Trigger reading time
It is the time in seconds that after a trigger signal on the digital input (ISO
IN), the reader performs an inventory operation (tag reading).
Note: Parameter used only when "Read mode" is "Trigger Mode".
Factory configuration: 1s | Values: 1 to 600s.
Filter time of the same
tag
Is the time in seconds of the read filter of the same tag, that is, the tag id is
sent to the PC/Controller on the first read and resent only after the time
configured in this field.
Factory configuration: 1s | Values: 0 to 600s.